Synthesizing Real-Time Ultrasound Images of Muscle Based on Biomechanical Simulation and Conditional Diffusion Network

Quantitative muscle function analysis based on ultrasound imaging, has been used for various applications, particularly with recent development of deep learning methods. The nature of speckle noises in ultrasound images poses challenges to accurate and reliable data annotation for supervised learning algorithms. To obtain a large and reliable dataset without manual scanning and labeling, we proposed a synthesizing pipeline to provide synthetic ultrasound datasets of muscle movement with an accurate ground truth, allowing augmenting, training, and evaluating models for different tasks. Our pipeline contained biomechanical simulation using a finite-element method (FEM), an algorithm for reconstructing sparse fascicles, and a diffusion network for ultrasound image generation. With the adjustment of a few parameters, the proposed pipeline can generate a large dataset of real-time ultrasound images with diversity in morphology and pattern. With 3030 ultrasound images generated, we qualitatively and quantitatively verified that the synthetic images closely matched with the in vivo images. In addition, we applied the synthetic dataset to different tasks of muscle analysis. Compared to trained on an unaugmented dataset, a model trained on synthetic one had better cross-dataset performance, which demonstrates the feasibility of synthesizing pipeline to augment model training and avoid overfitting. The results of the regression task show potentials under the conditions that the number of datasets or the accurate label is limited. The proposed synthesizing pipeline can not only be used for muscle-related study but also for other similar study and model development, where sequential images are needed for training.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-08-26
DOI
https://doi.org/10.1109/tuffc.2024.3445434
Citations
9
Primary Topic
Advanced Technologies in Various Fields
Type
article
Field-Weighted Citation Impact
3.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesizing Real-Time Ultrasound Images of Muscle Based on Biomechanical Simulation and Conditional Diffusion Network

Christina Zong‐Hao, Jianfa Wang, Yihao Zhou, Yong‐Ping Zheng et al.
9 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Advanced Technologies in Various Fields
3.13
article

Synthesizing Real-Time Ultrasound Images of Muscle Based on Biomechanical Simulation and Conditional Diffusion Network

Christina Zong‐Hao, Jianfa Wang, Yihao Zhou, Yong‐Ping Zheng, Zhen Song
article en
9 citations

Abstract

Quantitative muscle function analysis based on ultrasound imaging, has been used for various applications, particularly with recent development of deep learning methods. The nature of speckle noises in ultrasound images poses challenges to accurate and reliable data annotation for supervised learning algorithms. To obtain a large and reliable dataset without manual scanning and labeling, we proposed a synthesizing pipeline to provide synthetic ultrasound datasets of muscle movement with an accurate ground truth, allowing augmenting, training, and evaluating models for different tasks. Our pipeline contained biomechanical simulation using a finite-element method (FEM), an algorithm for reconstructing sparse fascicles, and a diffusion network for ultrasound image generation. With the adjustment of a few parameters, the proposed pipeline can generate a large dataset of real-time ultrasound images with diversity in morphology and pattern. With 3030 ultrasound images generated, we qualitatively and quantitatively verified that the synthetic images closely matched with the in vivo images. In addition, we applied the synthetic dataset to different tasks of muscle analysis. Compared to trained on an unaugmented dataset, a model trained on synthetic one had better cross-dataset performance, which demonstrates the feasibility of synthesizing pipeline to augment model training and avoid overfitting. The results of the regression task show potentials under the conditions that the number of datasets or the accurate label is limited. The proposed synthesizing pipeline can not only be used for muscle-related study but also for other similar study and model development, where sequential images are needed for training.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(11)
Hong Kong Polytechnic University (HK)
Affordable and clean energy
Openalex Percentile: Top 7%
Advanced Technologies in Various Fields
3.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.