Study on Readout Electronics of CEPC Scintillator Analog Hadronic Calorimeter Prototype

The circular electron positron collider (CEPC) is proposed to research Higgs, and particle flow algorithm (PFA) is expected to be adopted to obtain high energy resolution. As a PFA calorimeter, CEPC hadronic calorimeter (HCAL) features fine granularity, which necessitates high integration, low noise, and low power consumption in readout electronics. The scintillator-based analog HCAL (AHCAL), one of the PFA HCAL technical approaches, has been studied. In this article, a readout system of the CEPC AHCAL prototype is designed and implemented. The system can not only read the signals of high-density silicon photomultipliers (SiPMs) but also calibrate SiPM gain and monitor temperature. Testing of the electronics demonstrates that the noise and dynamic range performances meet the requirements. Following mess production and prototype integration, cosmic ray tests and beam tests are conducted, with all results verifying the functionality and performance of the readout system.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-08-26
DOI
https://doi.org/10.1109/tns.2024.3449282
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Readout Electronics of CEPC Scintillator Analog Hadronic Calorimeter Prototype

Yukun Shi, Yunlong Zhang, Zhongtao Shen, Shubin Liu et al.
IEEE Transactions on Nuclear Science
Radiation Detection and Scintillator Technologies
article

Study on Readout Electronics of CEPC Scintillator Analog Hadronic Calorimeter Prototype

Yukun Shi, Yunlong Zhang, Zhongtao Shen, Shubin Liu, Anshun Zhou, Hao Liu
article en

Abstract

The circular electron positron collider (CEPC) is proposed to research Higgs, and particle flow algorithm (PFA) is expected to be adopted to obtain high energy resolution. As a PFA calorimeter, CEPC hadronic calorimeter (HCAL) features fine granularity, which necessitates high integration, low noise, and low power consumption in readout electronics. The scintillator-based analog HCAL (AHCAL), one of the PFA HCAL technical approaches, has been studied. In this article, a readout system of the CEPC AHCAL prototype is designed and implemented. The system can not only read the signals of high-density silicon photomultipliers (SiPMs) but also calibrate SiPM gain and monitor temperature. Testing of the electronics demonstrates that the noise and dynamic range performances meet the requirements. Following mess production and prototype integration, cosmic ray tests and beam tests are conducted, with all results verifying the functionality and performance of the readout system.

IEEE Transactions on Nuclear ScienceVol. 72(3)
University of Science and Technology of China (CN)
National Natural Science Foundation of China, State Key Laboratory of Particle Detection and Electronics
Affordable and clean energy
Openalex Percentile: Top 86%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.