An Integrated Nitrogen-Vacancy Magnetometer With Subnanotesla Sensitivity for Practical Applications

The practical applications require the nitrogen-vacancy (NV) magnetometer to be transportable and highly sensitive. In this study, we have demonstrated a portable NV magnetometer consisting of a sensor head and miniaturized control system with a volume of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$22\times 19\times 12$ </tex-math></inline-formula> cm, which can operate outside the laboratory when connected to a computer. The sensor exhibited a sensitivity of 892.7 pT/Hz<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{\text {1/2}}$ </tex-math></inline-formula>, achieved through the use of a fluorescence omni-directional reflection concentrator (FORC) and common mode laser noise rejection (CMR) technology. Notably, the FORC increased the fluorescence collection efficiency to 57% by allowing the collection of fluorescence emitted from all six facets of the diamond. Our work is expected to facilitate the transition of NV magnetometers from a laboratory platform to practical applications.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-08-26
DOI
https://doi.org/10.1109/jsen.2024.3446867
Citations
7
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Integrated Nitrogen-Vacancy Magnetometer With Subnanotesla Sensitivity for Practical Applications

Jun Tang, Zhonghao Li, Zhenhua Liu, Hao Guo et al.
7 citations
IEEE Sensors Journal
Magnetic Field Sensors Techniques
1.46
article

An Integrated Nitrogen-Vacancy Magnetometer With Subnanotesla Sensitivity for Practical Applications

Jun Tang, Zhonghao Li, Zhenhua Liu, Hao Guo, Zongmin Ma, Doudou Zheng, Jianghao Fu, Huanfei Wen, Jun Liu
article en
7 citations

Abstract

The practical applications require the nitrogen-vacancy (NV) magnetometer to be transportable and highly sensitive. In this study, we have demonstrated a portable NV magnetometer consisting of a sensor head and miniaturized control system with a volume of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$22\times 19\times 12$ </tex-math></inline-formula> cm, which can operate outside the laboratory when connected to a computer. The sensor exhibited a sensitivity of 892.7 pT/Hz<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{\text {1/2}}$ </tex-math></inline-formula>, achieved through the use of a fluorescence omni-directional reflection concentrator (FORC) and common mode laser noise rejection (CMR) technology. Notably, the FORC increased the fluorescence collection efficiency to 57% by allowing the collection of fluorescence emitted from all six facets of the diamond. Our work is expected to facilitate the transition of NV magnetometers from a laboratory platform to practical applications.

IEEE Sensors JournalVol. 24(21)
North University of China (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 18%
Magnetic Field Sensors Techniques
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.