The MICADO first light imager for the ELT: he detector positioning system of MICADO

The Detector Positioning System (DPS) is a cryogenic mechanism operating at 82 K installed in the cryostat of the Multi- AO Imaging Camera for Deep Observations (MICADO) at the Extremely Large Telescope (ELT). <br/> The DPS mechanism will be exclusively utilized during the alignment and test phase. Upon completing the test phase, it will be mechanically locked at the best pre-determined focus so that it cannot be moved during the observation period. <br/> The DPS has been conceptualized as a fixed and reproducible interface to the Main Bench Structure in the MICADO cryostat and as an adjustable unit containing the Detector Array mounted on the DPS frame installed on a linear guide on the base plate. A cryogenic linear actuator further acts as the linear guide during the alignment phase to bring the focal plane array into focus.

Authors

Institutions

Publication Details

Published
2024-08-26
DOI
https://doi.org/10.1117/12.3018338
Citations
1
Primary Topic
Adaptive optics and wavefront sensing
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The MICADO first light imager for the ELT: he detector positioning system of MICADO

Mathias Honsberg, Matthias Deysenroth, Andreas Emslander, M. Haug et al.
1 citations
Adaptive optics and wavefront sensing
0.34
article

The MICADO first light imager for the ELT: he detector positioning system of MICADO

Mathias Honsberg, Matthias Deysenroth, Andreas Emslander, M. Haug, Naidu Bezawada, Kateryna Kravchenko, Dirk Kampf, Florian Läng, N. Ageorges, Federico Biondi, Lenard Spallek, Luis Neumeier, Veronika Wimmer, Aysun Soenmez, Lothar Barl, S. Rabien
article en
1 citations

Abstract

The Detector Positioning System (DPS) is a cryogenic mechanism operating at 82 K installed in the cryostat of the Multi- AO Imaging Camera for Deep Observations (MICADO) at the Extremely Large Telescope (ELT). <br/> The DPS mechanism will be exclusively utilized during the alignment and test phase. Upon completing the test phase, it will be mechanically locked at the best pre-determined focus so that it cannot be moved during the observation period. <br/> The DPS has been conceptualized as a fixed and reproducible interface to the Main Bench Structure in the MICADO cryostat and as an adjustable unit containing the Detector Array mounted on the DPS frame installed on a linear guide on the base plate. A cryogenic linear actuator further acts as the linear guide during the alignment phase to bring the focal plane array into focus.

Vol. 12182
Max Planck Institute for Extraterrestrial Physics (DE), Teles (Germany) (DE)
Affordable and clean energy
Openalex Percentile: Top 41%
Adaptive optics and wavefront sensing
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.