The method of Pb-212 measurements in air with the application of the LSC technique

This paper describes a method enabling the measurement of the potential alpha energy concentration (PAEC) of thoron decay products based on the determined concentration of lead 212 Pb (T 1/2 = 10.64 h) in the air [Lever et al., 2003]. A liquid scintillation spectrometer was used to determine the concentration of the 212 Pb isotope, and the sample was taken by pumping air through a filter where thoron decay products were stored. This method can be classified as integrating because the sample takes several hours, and the measurement results in one value for the entire sampling period. Measurements were carried out in laboratory conditions, in a climatic chamber where a constant supply of thoron was maintained, and in environmental conditions, in the basement of the family house and outdoors. Sampling took from 12 to 48 h. This article presents the preliminary results of the study. The obtained results were in the range of 170–195 Bq/m 3 in the case of laboratory measurements and from 0.04 to 0.79 Bq/m 3 in the case of environmental measurements. Based on the obtained results, the potential alpha energy concentration (PAEC) was calculated. The application of the low-level LS spectrometer allows for the achievement of a lower limit of detection (LLD) at level 0.04–0.05 Bq/m 3 , while the use of the portable LS spectrometer allows for the measurement of deficient 212 Pb concentrations in the range of 0.4–0.5 Bq/m 3 . The obtained results confirm that the method is suitable for determining the concentration of 212 Pb and, consequently, assessing exposure to thoron progeny. • It is possible to use the LSC method for Pb-212 measurements in air. • Application of LSC methods allows easy estimation of PAEC values. • It is a very promising method of thoron hazard monitoring.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2024-08-26
DOI
https://doi.org/10.1016/j.radmeas.2024.107278
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The method of Pb-212 measurements in air with the application of the LSC technique

Agata Grygier, Stanisław Chałupnik
Radiation Measurements
Nuclear Physics and Applications
article

The method of Pb-212 measurements in air with the application of the LSC technique

Agata Grygier, Stanisław Chałupnik
article en

Abstract

This paper describes a method enabling the measurement of the potential alpha energy concentration (PAEC) of thoron decay products based on the determined concentration of lead 212 Pb (T 1/2 = 10.64 h) in the air [Lever et al., 2003]. A liquid scintillation spectrometer was used to determine the concentration of the 212 Pb isotope, and the sample was taken by pumping air through a filter where thoron decay products were stored. This method can be classified as integrating because the sample takes several hours, and the measurement results in one value for the entire sampling period. Measurements were carried out in laboratory conditions, in a climatic chamber where a constant supply of thoron was maintained, and in environmental conditions, in the basement of the family house and outdoors. Sampling took from 12 to 48 h. This article presents the preliminary results of the study. The obtained results were in the range of 170–195 Bq/m 3 in the case of laboratory measurements and from 0.04 to 0.79 Bq/m 3 in the case of environmental measurements. Based on the obtained results, the potential alpha energy concentration (PAEC) was calculated. The application of the low-level LS spectrometer allows for the achievement of a lower limit of detection (LLD) at level 0.04–0.05 Bq/m 3 , while the use of the portable LS spectrometer allows for the measurement of deficient 212 Pb concentrations in the range of 0.4–0.5 Bq/m 3 . The obtained results confirm that the method is suitable for determining the concentration of 212 Pb and, consequently, assessing exposure to thoron progeny. • It is possible to use the LSC method for Pb-212 measurements in air. • Application of LSC methods allows easy estimation of PAEC values. • It is a very promising method of thoron hazard monitoring.

Radiation MeasurementsVol. 178
Central Mining Institute (PL)
Affordable and clean energy
Openalex Percentile: Top 86%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.