Screen-printed, biocompatible and ultrasensitive sensor for real-time reactive oxygen species detection in human sweat

Excessive or burst generation of reactive oxygen species (ROS) can induce oxidative stress, precipitating a range of critical illnesses, including cancers, Parkinson's disease and Ischemia-reperfusion injury. Conventional biological assays for ROS, involving discrete steps of capturing, labelling, and spectrometric detection, are complex and time-intensive. Moreover, their accuracy is substantially compromised by the short lifespan (microseconds to milliseconds) of ROS. Consequently, there is a pressing need for a rapid and efficient method that enables real-time detection. In this study, we have developed a printable, flexible ROS sensor based on a robust nanoenzyme composite by direct deposition of the paste onto a flexible polyethylene terephthalate (PET) substrate. This device demonstrated the fast and real-time responses to the hydrogen peroxide (mimetic agent) in the laboratory and to total ROS in sweat of an individual, exhibiting an outstanding current response to hydrogen peroxide across a broad concentration range of 0.01-10 mM, with a limit of detection (LOD) of 1.85 μM. The device's sensitivity to hydrogen peroxide (136.59 μA mM<sup>-1</sup> cm<sup>-2</sup>), was found to be 1.5 to 10 times higher than that of sensors previously reported. Moreover, the IFRS device successfully identified instantaneous ROS levels in the sweat of adult males in vitro, with amperometric response increased 8 times after half an hour strenuous exercise, thereby exhibiting excellent selectivity, remarkable stability, and confirmed high biosafety. Overall, the IFRS provides a viable and practical solution for simple, expedited, and real-time ROS detection in the near future.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2024-08-26
DOI
https://doi.org/10.1016/j.talanta.2024.126774
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Screen-printed, biocompatible and ultrasensitive sensor for real-time reactive oxygen species detection in human sweat

Zhiqiang Zhai, Yin Long, Xiaosong Du, Jun Li et al.
2 citations
Talanta
Analytical Chemistry and Sensors
0.58
article

Screen-printed, biocompatible and ultrasensitive sensor for real-time reactive oxygen species detection in human sweat

Zhiqiang Zhai, Yin Long, Xiaosong Du, Jun Li, Rui Liao, Yadong Jiang, Heng Zheng, Yang Wang
article en
2 citations

Abstract

Excessive or burst generation of reactive oxygen species (ROS) can induce oxidative stress, precipitating a range of critical illnesses, including cancers, Parkinson's disease and Ischemia-reperfusion injury. Conventional biological assays for ROS, involving discrete steps of capturing, labelling, and spectrometric detection, are complex and time-intensive. Moreover, their accuracy is substantially compromised by the short lifespan (microseconds to milliseconds) of ROS. Consequently, there is a pressing need for a rapid and efficient method that enables real-time detection. In this study, we have developed a printable, flexible ROS sensor based on a robust nanoenzyme composite by direct deposition of the paste onto a flexible polyethylene terephthalate (PET) substrate. This device demonstrated the fast and real-time responses to the hydrogen peroxide (mimetic agent) in the laboratory and to total ROS in sweat of an individual, exhibiting an outstanding current response to hydrogen peroxide across a broad concentration range of 0.01-10 mM, with a limit of detection (LOD) of 1.85 μM. The device's sensitivity to hydrogen peroxide (136.59 μA mM<sup>-1</sup> cm<sup>-2</sup>), was found to be 1.5 to 10 times higher than that of sensors previously reported. Moreover, the IFRS device successfully identified instantaneous ROS levels in the sweat of adult males in vitro, with amperometric response increased 8 times after half an hour strenuous exercise, thereby exhibiting excellent selectivity, remarkable stability, and confirmed high biosafety. Overall, the IFRS provides a viable and practical solution for simple, expedited, and real-time ROS detection in the near future.

TalantaVol. 280
University of Wisconsin–Madison (US), University of Electronic Science and Technology of China (CN), Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital (CN), National Engineering Research Center of Electromagnetic Radiation Control Materials (CN)
Life below water
Openalex Percentile: Top 38%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.