Overview and current challenges at the Calibration Laboratory of the Paul Scherrer Institute

The Calibration Laboratory of the Paul Scherrer Institute (PSI) is a secondary calibration laboratory accredited by the Swiss Accreditation Service (SAS) in accordance with ISO 17025. It also acts as a verification body authorized by the Swiss Federal Institute of Metrology (METAS). The Laboratory is equipped with X-ray, gamma and neutron irradiation facilities, providing characterized reference radiation fields for gamma 137 Cs, 60 Co, narrow spectrum X-rays from N-15 to N-300 and neutron radionuclide sources 252 Cf, 252 Cf (D2O-moderated) and 241 Am-Be. The laboratory performs routine calibrations, organizes intercomparison measurements for individual monitoring services in Switzerland, and participates in various research projects, e.g., by performing irradiations in reference fields. For this reason, the proper characterization of reference radiation fields is of utmost importance for ensuring high quality irradiations and calibrations of personal dosemeters and radiation protection instruments. In this contribution, we provide an overview of the irradiation facilities at the Calibration Laboratory at PSI and discuss the challenges of characterizing reference radiation fields. In particular, we will discuss the factors affecting the determination of the distance between the source and irradiated dosemeters and detectors, as well as issues related to 252 Cf decay and contribution of 250 Cf. We will also demonstrate the use of Monte-Carlo simulations in determining the optimal position of the source and irradiation facility within the irradiation room. • Monte Carlo Simulation quantifies neutron backscattering in reference field. • Systematic deviations identified during regular control measurements. • A new method based on control measurements estimates initial 250 Cf content in 252 Cf source.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2024-08-26
DOI
https://doi.org/10.1016/j.radmeas.2024.107273
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overview and current challenges at the Calibration Laboratory of the Paul Scherrer Institute

E.G. Yukihara, Alberto Stabilini, Sabine Mayer, M. U. Sliz et al.
1 citations
Radiation Measurements
Nuclear Physics and Applications
0.61
article

Overview and current challenges at the Calibration Laboratory of the Paul Scherrer Institute

E.G. Yukihara, Alberto Stabilini, Sabine Mayer, M. U. Sliz, Gernot Butterweck, Federico Alejandro Geser, M. Kasprzak
article en
1 citations

Abstract

The Calibration Laboratory of the Paul Scherrer Institute (PSI) is a secondary calibration laboratory accredited by the Swiss Accreditation Service (SAS) in accordance with ISO 17025. It also acts as a verification body authorized by the Swiss Federal Institute of Metrology (METAS). The Laboratory is equipped with X-ray, gamma and neutron irradiation facilities, providing characterized reference radiation fields for gamma 137 Cs, 60 Co, narrow spectrum X-rays from N-15 to N-300 and neutron radionuclide sources 252 Cf, 252 Cf (D2O-moderated) and 241 Am-Be. The laboratory performs routine calibrations, organizes intercomparison measurements for individual monitoring services in Switzerland, and participates in various research projects, e.g., by performing irradiations in reference fields. For this reason, the proper characterization of reference radiation fields is of utmost importance for ensuring high quality irradiations and calibrations of personal dosemeters and radiation protection instruments. In this contribution, we provide an overview of the irradiation facilities at the Calibration Laboratory at PSI and discuss the challenges of characterizing reference radiation fields. In particular, we will discuss the factors affecting the determination of the distance between the source and irradiated dosemeters and detectors, as well as issues related to 252 Cf decay and contribution of 250 Cf. We will also demonstrate the use of Monte-Carlo simulations in determining the optimal position of the source and irradiation facility within the irradiation room. • Monte Carlo Simulation quantifies neutron backscattering in reference field. • Systematic deviations identified during regular control measurements. • A new method based on control measurements estimates initial 250 Cf content in 252 Cf source.

Radiation MeasurementsVol. 177
Paul Scherrer Institute (CH)
Eidgenössisches Nuklearsicherheitsinspektorat
Openalex Percentile: Top 32%
Nuclear Physics and Applications
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.