An Effective and Robust Parameter Estimation Method in a Self-Developed, Ultra-Low Frequency Impedance Spectroscopy Technique for Large Impedances

Bioimpedance spectrum (BIS) measurements are highly appreciated in in vivo studies. This non-destructive method, supported by simple and efficient instrumentation, is widely used in clinical applications. The multi-frequency approach allows for the efficient extraction of the most information from the measured data. However, low-frequency implementations are still unexploited in the development of the technique. A self-developed BIS measurement technology is considered the pioneering approach for low (<5 kHz) and ultra-low (<100 Hz) frequency range studies. In this paper, the robustness of ultra-low frequency measurements in the prototypes is examined using specially constructed physical models and a dedicated neural network-based software. The physical models were designed to model the dispersion mainly in the ultra-low frequency range. The first set of models was used in the training of the software environment, while the second set allowed a complete verification of the technology. Further, the Hilbert transformation was employed to adjust the imaginary components of complex signals and for phase determination. The findings showed that the prototypes are capable of efficient and robust data acquisition, regardless of the applied frequency range, minimizing the impact of measurement errors. Consequently, in in vivo applications, these prototypes minimize the variance of the measurement results, allowing the resulting BIS data to provide a maximum representation of biological phenomena.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-08-20
DOI
https://doi.org/10.3390/electronics13163300
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Effective and Robust Parameter Estimation Method in a Self-Developed, Ultra-Low Frequency Impedance Spectroscopy Technique for Large Impedances

Nina Győrfi, Mirjana Šiljegović, Ákos Odry, Levente Kovács et al.
1 citations
Electronics
Electrical and Bioimpedance Tomography
0.21
article

An Effective and Robust Parameter Estimation Method in a Self-Developed, Ultra-Low Frequency Impedance Spectroscopy Technique for Large Impedances

Nina Győrfi, Mirjana Šiljegović, Ákos Odry, Levente Kovács, Zoltán Vizvári, Bojan Kuljić, Vladimir Tadić, Katalin Juhos, Flórián Kovács, Mihály Klincsik, Tibor Szakáll, István Kecskés, Péter Odry, Zoltán Sari
article en
1 citations

Abstract

Bioimpedance spectrum (BIS) measurements are highly appreciated in in vivo studies. This non-destructive method, supported by simple and efficient instrumentation, is widely used in clinical applications. The multi-frequency approach allows for the efficient extraction of the most information from the measured data. However, low-frequency implementations are still unexploited in the development of the technique. A self-developed BIS measurement technology is considered the pioneering approach for low (<5 kHz) and ultra-low (<100 Hz) frequency range studies. In this paper, the robustness of ultra-low frequency measurements in the prototypes is examined using specially constructed physical models and a dedicated neural network-based software. The physical models were designed to model the dispersion mainly in the ultra-low frequency range. The first set of models was used in the training of the software environment, while the second set allowed a complete verification of the technology. Further, the Hilbert transformation was employed to adjust the imaginary components of complex signals and for phase determination. The findings showed that the prototypes are capable of efficient and robust data acquisition, regardless of the applied frequency range, minimizing the impact of measurement errors. Consequently, in in vivo applications, these prototypes minimize the variance of the measurement results, allowing the resulting BIS data to provide a maximum representation of biological phenomena.

ElectronicsVol. 13(16)
Obuda University (HU), Magyar Agrár- és Élettudományi Egyetem (HU), University of Novi Sad (RS), University of Szeged (HU), Technical College of Applied Sciences (RS), University of Pecs (HU), University of Dunaújváros (HU)
Pécsi Tudományegyetem
Openalex Percentile: Top 49%
Electrical and Bioimpedance Tomography
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.