Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism

Purpose: This study aimed to compare the safety, efficacy, and visual outcomes of 80-microns LASIK versus 100-microns LASIK in managing myopia and myopic astigmatism. The study was conducted at a tertiary care hospital in North India. Methods: This was a prospective contralateral eye study that included patients with myopia and myopic astigmatism seeking refractive correction. The eligibility criteria included normal corneal topography, an epithelial thickness less than 60 microns, a calculated percentage tissue ablation (with 100-microns flap) less than 40%, a calculated residual stromal bed thickness (with 100-microns flap) more than 300 microns, and willingness to participate and follow up. Patients with glaucoma, cataracts, other visually disabling ocular pathologies, and a history of past ocular surgery were excluded. All patients underwent LASIK with 80-microns LASIK in one eye and 100-microns LASIK in the other eye. The patients were followed up for 6 months, and the results were analyzed. Results: The study included 216 eyes of 108 patients. The mean preoperative spherical equivalent in the 80-microns group and the 100-microns group was -3.53 ± 1.81 and -3.69 ± 1.32 diopters, respectively ( P = 0.78). The mean 6 months decimal postoperative UCVA was 0.98 ± 0.13 in the 80-microns group and 0.97 ± 0.14 in the 100-microns group ( P = 0.99). The postoperative change in the higher-order aberration profile was comparable in both groups ( P = 0.78). The percentage tissue ablation was significantly lower in the 80-microns group ( P = 0.002). The incidence of flap micro striae and OBL was higher in the 80-microns group, while neither of these had any visual implications. Conclusion: The study concluded that 80-microns LASIK is an efficacious and safe alternative to 100-micron LASIK, especially useful in patients with higher myopia.

Authors

Institutions

Publication Details

Journal
Indian Journal of Ophthalmology
Published
2024-08-23
DOI
https://doi.org/10.4103/ijo.ijo_3213_23
Citations
1
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism

Aishwarya Rathod, Saumya Kumar, Deeksha Rani, Hemant Jhajharia et al.
1 citations
Indian Journal of Ophthalmology
Corneal surgery and disorders
0.40
article

Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism

Aishwarya Rathod, Saumya Kumar, Deeksha Rani, Hemant Jhajharia, Sudarshan Khokhar, Sarika Rajput
article en
1 citations

Abstract

Purpose: This study aimed to compare the safety, efficacy, and visual outcomes of 80-microns LASIK versus 100-microns LASIK in managing myopia and myopic astigmatism. The study was conducted at a tertiary care hospital in North India. Methods: This was a prospective contralateral eye study that included patients with myopia and myopic astigmatism seeking refractive correction. The eligibility criteria included normal corneal topography, an epithelial thickness less than 60 microns, a calculated percentage tissue ablation (with 100-microns flap) less than 40%, a calculated residual stromal bed thickness (with 100-microns flap) more than 300 microns, and willingness to participate and follow up. Patients with glaucoma, cataracts, other visually disabling ocular pathologies, and a history of past ocular surgery were excluded. All patients underwent LASIK with 80-microns LASIK in one eye and 100-microns LASIK in the other eye. The patients were followed up for 6 months, and the results were analyzed. Results: The study included 216 eyes of 108 patients. The mean preoperative spherical equivalent in the 80-microns group and the 100-microns group was -3.53 ± 1.81 and -3.69 ± 1.32 diopters, respectively ( P = 0.78). The mean 6 months decimal postoperative UCVA was 0.98 ± 0.13 in the 80-microns group and 0.97 ± 0.14 in the 100-microns group ( P = 0.99). The postoperative change in the higher-order aberration profile was comparable in both groups ( P = 0.78). The percentage tissue ablation was significantly lower in the 80-microns group ( P = 0.002). The incidence of flap micro striae and OBL was higher in the 80-microns group, while neither of these had any visual implications. Conclusion: The study concluded that 80-microns LASIK is an efficacious and safe alternative to 100-micron LASIK, especially useful in patients with higher myopia.

Indian Journal of OphthalmologyVol. 72(9)
All India Institute of Medical Sciences (IN)
Good health and well-being
Openalex Percentile: Top 36%
Corneal surgery and disorders
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.