Pulse Pressure and Acute Brain Injury in Venoarterial Extracorporeal Membrane Oxygenation: An Extracorporeal Life Support Organization Registry Analysis

Low pulse pressure (PP) in venoarterial-extracorporeal membrane oxygenation (VA-ECMO) is a marker of cardiac dysfunction and has been associated with acute brain injury (ABI) as continuous-flow centrifugal pump may lead to endothelial dysregulation. We retrospectively analyzed adults (≥18 years) receiving "peripheral" VA-ECMO for cardiogenic shock in the Extracorporeal Life Support Organization Registry (January 2018-July 2023). Acute brain injury (our primary outcome) included central nervous system (CNS) ischemia, intracranial hemorrhage, brain death, and seizures. Multivariable logistic regressions were performed to examine whether PP ≤10 mm Hg was associated with ABI. Of 9,807 peripheral VA-ECMO patients (median age = 57.4 years, 67% = male), 8,294 (85%) had PP >10 mm Hg versus 1,513 (15%) had PP ≤10 mm Hg. Patients with PP ≤10 mm Hg experienced ABI more frequently versus PP >10 mm Hg (15% versus 11%, p < 0.001). After adjustment, PP ≤10 mm Hg was independently associated with ABI (adjusted odds ratio [aOR] = 1.25, 95% confidence interval [CI] = 1.06-1.48, p = 0.01). Central nervous system ischemia and brain death were more common in patients with PP ≤10 versus PP >10 mm Hg (8% versus 6%, p = 0.008; 3% versus 1%, p < 0.001). Pulse pressure ≤10 mm Hg was associated with CNS ischemia (aOR = 1.26, 95% CI = 1.02-1.56, p = 0.03) but not intracranial hemorrhage (aOR = 1.14, 95% CI = 0.85-1.54, p = 0.38). Early low PP (≤10 mm Hg) at 24 hours of ECMO support was associated with ABI, particularly CNS ischemia, in peripheral VA-ECMO patients.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2024-08-23
DOI
https://doi.org/10.1097/mat.0000000000002294
Citations
14
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
2.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse Pressure and Acute Brain Injury in Venoarterial Extracorporeal Membrane Oxygenation: An Extracorporeal Life Support Organization Registry Analysis

Patricia M. Brown, Akram Zaaqoq, Marc Anders, Christopher Wilcox et al.
14 citations
ASAIO Journal
Mechanical Circulatory Support Devices
2.58
article

Pulse Pressure and Acute Brain Injury in Venoarterial Extracorporeal Membrane Oxygenation: An Extracorporeal Life Support Organization Registry Analysis

Patricia M. Brown, Akram Zaaqoq, Marc Anders, Christopher Wilcox, Daniel Brodie, Benjamin L. Shou, Peter T. Rycus, Jin Kook Kang, Andrew Kalra, Sung‐Min Cho, Glenn J.R. Whitman
article en
14 citations

Abstract

Low pulse pressure (PP) in venoarterial-extracorporeal membrane oxygenation (VA-ECMO) is a marker of cardiac dysfunction and has been associated with acute brain injury (ABI) as continuous-flow centrifugal pump may lead to endothelial dysregulation. We retrospectively analyzed adults (≥18 years) receiving "peripheral" VA-ECMO for cardiogenic shock in the Extracorporeal Life Support Organization Registry (January 2018-July 2023). Acute brain injury (our primary outcome) included central nervous system (CNS) ischemia, intracranial hemorrhage, brain death, and seizures. Multivariable logistic regressions were performed to examine whether PP ≤10 mm Hg was associated with ABI. Of 9,807 peripheral VA-ECMO patients (median age = 57.4 years, 67% = male), 8,294 (85%) had PP >10 mm Hg versus 1,513 (15%) had PP ≤10 mm Hg. Patients with PP ≤10 mm Hg experienced ABI more frequently versus PP >10 mm Hg (15% versus 11%, p < 0.001). After adjustment, PP ≤10 mm Hg was independently associated with ABI (adjusted odds ratio [aOR] = 1.25, 95% confidence interval [CI] = 1.06-1.48, p = 0.01). Central nervous system ischemia and brain death were more common in patients with PP ≤10 versus PP >10 mm Hg (8% versus 6%, p = 0.008; 3% versus 1%, p < 0.001). Pulse pressure ≤10 mm Hg was associated with CNS ischemia (aOR = 1.26, 95% CI = 1.02-1.56, p = 0.03) but not intracranial hemorrhage (aOR = 1.14, 95% CI = 0.85-1.54, p = 0.38). Early low PP (≤10 mm Hg) at 24 hours of ECMO support was associated with ABI, particularly CNS ischemia, in peripheral VA-ECMO patients.

ASAIO JournalVol. 71(2)
Royal Historical Society (GB), Apple (Israel) (IL), Mercy Medical Center (US), Johns Hopkins University (US), Thomas Jefferson University (US), Baylor College of Medicine (US), Johns Hopkins Medicine (US), Ider University (MN), Johns Hopkins Hospital (US), Mercy Hospital (US), University of Virginia (US)
Johns Hopkins University, LivaNova, Abiomed, Xenios, National Heart, Lung, and Blood Institute
Responsible consumption and production
Openalex Percentile: Top 10%
Mechanical Circulatory Support Devices
2.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.