Study of the stress-strain state of models of various options for osteosynthesis of tibia bones with diaphyseal fractures in the middle third in children with imperfect osteogenesis and incomplete growth. Part 2. Torsion

Background. Osteogenesis imperfecta is accompanied by multiple fractures of skeletal bones, the development of progressive deformations of the limb bones and, as a result, impaired support, and walking. The most common mean for stabilizing bone fragments in the treatment of fractures due to osteogenesis imperfecta are intramedullary fixators of various designs. The treatment of this disease requires a long time, therefore, the use of internal fixators without the possibility of their extension during skeletal growth leads to an increase in the frequency of repeated surgical interventions due to the need for their replacement. Goal: to investigate the stress-strain state of the lower leg models under the influence of torsional load in conditions of a fracture of both bones in the middle third and their osteosynthesis using intramedullary rods of various designs in children with osteogenesis imperfecta and incomplete growth. Materials and methods. Mathematical modeling was carried out of two options for osteosynthesis of tibia bones with a fracture in the middle third in children with osteogenesis imperfecta: 1) a rod without rotational stability; 2) a rod with rotational stability. During the research, the stress-strain state of the models under the influence of torsional load was studied. Results. A rod with rotational stability during tibial osteosynthesis allows reducing the stress along the fracture line to 0.3 MPa. In other zones, the stress remains at the same level as when using a rotationally unstable rod. The main advantage provided by a rod with rotational stability in tibial osteosynthesis under the influence of torsional loads is the reduction of the stress along the fracture line to 0.3 MPa, which is important in the treatment of children with osteogenesis imperfecta. Conclusions. Under torsional loads, a rod with rotational stability provides a 10 times lower stress along the fracture line compared to a rotationally unstable rod.

Authors

Institutions

Publication Details

Journal
TRAUMA
Published
2024-08-23
DOI
https://doi.org/10.22141/1608-1706.3.25.2024.977
Primary Topic
Medical and Biological Sciences
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the stress-strain state of models of various options for osteosynthesis of tibia bones with diaphyseal fractures in the middle third in children with imperfect osteogenesis and incomplete growth. Part 2. Torsion

О.V. Yaresko, М.Yu. Karpinsky, Mykola Korzh, E.S. Katsalap et al.
TRAUMA
Medical and Biological Sciences
article

Study of the stress-strain state of models of various options for osteosynthesis of tibia bones with diaphyseal fractures in the middle third in children with imperfect osteogenesis and incomplete growth. Part 2. Torsion

О.V. Yaresko, М.Yu. Karpinsky, Mykola Korzh, E.S. Katsalap, S.O. Khmyzov
article en

Abstract

Background. Osteogenesis imperfecta is accompanied by multiple fractures of skeletal bones, the development of progressive deformations of the limb bones and, as a result, impaired support, and walking. The most common mean for stabilizing bone fragments in the treatment of fractures due to osteogenesis imperfecta are intramedullary fixators of various designs. The treatment of this disease requires a long time, therefore, the use of internal fixators without the possibility of their extension during skeletal growth leads to an increase in the frequency of repeated surgical interventions due to the need for their replacement. Goal: to investigate the stress-strain state of the lower leg models under the influence of torsional load in conditions of a fracture of both bones in the middle third and their osteosynthesis using intramedullary rods of various designs in children with osteogenesis imperfecta and incomplete growth. Materials and methods. Mathematical modeling was carried out of two options for osteosynthesis of tibia bones with a fracture in the middle third in children with osteogenesis imperfecta: 1) a rod without rotational stability; 2) a rod with rotational stability. During the research, the stress-strain state of the models under the influence of torsional load was studied. Results. A rod with rotational stability during tibial osteosynthesis allows reducing the stress along the fracture line to 0.3 MPa. In other zones, the stress remains at the same level as when using a rotationally unstable rod. The main advantage provided by a rod with rotational stability in tibial osteosynthesis under the influence of torsional loads is the reduction of the stress along the fracture line to 0.3 MPa, which is important in the treatment of children with osteogenesis imperfecta. Conclusions. Under torsional loads, a rod with rotational stability provides a 10 times lower stress along the fracture line compared to a rotationally unstable rod.

TRAUMAVol. 25(3)
Sytenko Institute of Spine and Joint Pathology of the National Academy of Medical Sciences of Ukraine (UA)
Good health and well-being
Openalex Percentile: Top 69%
Medical and Biological Sciences
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.