Interpreting the main effects on the efficiency and morphology for establishing a procedure of electrodepositing Zn from purified chloride SPL solutions

Abstract Potentiodynamic and galvanostatic experiments have been used to investigate the electrodeposition of Zn and to develop a reliable recovery method from a purified spent pickling liquor (SPL) of hot dip galvanization. The main bjective was to find the suitable conditions to deposit high-grade Zn from the purified ZnCl 2 –HCl–NaCl solution in a conventional electrowinning cell holding the stationary electrolyte. The effects of pH (1.5–4.5) in and Zn concentration (30–150 g/dm 3 ) in the stationary electrolytes were studied first by the potentiodynamic method to reveal the major characteristics of the cathodic process and to give reference for further practical examinations by the galvanostatic technique. The electrowinning experiments pointed out the effects of these major parameters, beside other practical factors, like apparent current density (c.d.) and additional NaCl concentration. The long-term galvanostatic experiments proved that the current efficiency (c.e.) increases significantly as the pH and the Zn concentration are increased. A c.e. of ~ 99% can be reached with an electrolyte of pH ~ 5, Zn concentration ~ 50 g/dm 3 applying a c.d. in the 300–600 A/m 2 range. Increasing the Zn concentration could considerably improve also the deposit morphology. The addition of NaCl can practically improve the c.e. if the Zn concentration is at least around 50 g/dm 3 . In contrast, this improvement is largely off-set by the negative effects of strong H 2 evolution at low (e.g. < 10 g/dm 3 ) Zn concentrations. Extremely high Cl − ion concentrations, however, inhibit the cathodic reaction by stronger chloro-complex formation. In this case the intensive H + reduction causes hydroxide precipitation.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2024-08-21
DOI
https://doi.org/10.1007/s42452-024-06142-3
Citations
2
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interpreting the main effects on the efficiency and morphology for establishing a procedure of electrodepositing Zn from purified chloride SPL solutions

Tamás Kékesi, István B. Illés, Hanna Zakiyya
2 citations
Discover Applied Sciences
Advanced battery technologies research
0.42
article

Interpreting the main effects on the efficiency and morphology for establishing a procedure of electrodepositing Zn from purified chloride SPL solutions

Tamás Kékesi, István B. Illés, Hanna Zakiyya
article en
2 citations

Abstract

Abstract Potentiodynamic and galvanostatic experiments have been used to investigate the electrodeposition of Zn and to develop a reliable recovery method from a purified spent pickling liquor (SPL) of hot dip galvanization. The main bjective was to find the suitable conditions to deposit high-grade Zn from the purified ZnCl 2 –HCl–NaCl solution in a conventional electrowinning cell holding the stationary electrolyte. The effects of pH (1.5–4.5) in and Zn concentration (30–150 g/dm 3 ) in the stationary electrolytes were studied first by the potentiodynamic method to reveal the major characteristics of the cathodic process and to give reference for further practical examinations by the galvanostatic technique. The electrowinning experiments pointed out the effects of these major parameters, beside other practical factors, like apparent current density (c.d.) and additional NaCl concentration. The long-term galvanostatic experiments proved that the current efficiency (c.e.) increases significantly as the pH and the Zn concentration are increased. A c.e. of ~ 99% can be reached with an electrolyte of pH ~ 5, Zn concentration ~ 50 g/dm 3 applying a c.d. in the 300–600 A/m 2 range. Increasing the Zn concentration could considerably improve also the deposit morphology. The addition of NaCl can practically improve the c.e. if the Zn concentration is at least around 50 g/dm 3 . In contrast, this improvement is largely off-set by the negative effects of strong H 2 evolution at low (e.g. < 10 g/dm 3 ) Zn concentrations. Extremely high Cl − ion concentrations, however, inhibit the cathodic reaction by stronger chloro-complex formation. In this case the intensive H + reduction causes hydroxide precipitation.

Discover Applied SciencesVol. 6(9)
University of Miskolc (HU), Universitas Negeri Surabaya (ID)
Tempus Közalapítvány
Clean water and sanitation
Openalex Percentile: Top 39%
Advanced battery technologies research
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.