Microplastics and dye removal from textile wastewater using MIL-53 (Fe) metal-organic framework-based ultrafiltration membranes

Microplastics (MPs) and other organic matters in textile wastewater have posed a formidable challenge for treatment processes, particularly in the primary stages such as ultrafiltration (UF). UF plays a crucial role in preventing the entry of pollutants into subsequent treatment steps. However, the performance efficiency of UF membranes is compromised by the potential fouling of membrane pores by MPs, dyes and other organic pollutants such as bovine serum albumin (BSA). This study focuses on enhancing UF membrane performance, specifically its antifouling properties, through the development of high-performance membranes using MIL-53(Fe) metal-organic framework (MOF) particles (noted as MIL-53 here). Various concentrations of the MIL-53 (0.05, 0.1, 0.2, and 0.5 wt%) were integrated into the membrane structure through phase inversion process. Streaming zeta potential results confirmed the negatively charged surface of the membranes and their high hydrophilicity was validated through contact angle analysis. FTIR, SEM, EDS, and XRD confirmed the presence of MIL-53 particles on the surface of membranes. The developed membranes were tested for 24 h to assess their antifouling properties, with a subsequent 30-min hydraulic flush to measure their flux recovery ratios. Methylene Blue (MB) dye was used as a cationic dye present in textile wastewater to evaluate the efficiency of the developed membranes in dye removal and the synergistic effects of dye rejection in the presence of organic matters (i.e., MPs and BSA). Since previous studies have not fully addressed the combination of dyes and organic matter, this study thoroughly investigated the effect of particle-type foulants (MPs) and their interactions with dye (MB), as well as water soluble protein-type foulants (BSA) and their interaction with MB. The results indicated that the developed membranes exhibited higher MB rejection when the dye was present with either MP or BSA, along with improved antifouling properties. The optimised UF membrane integrated with 0.1 wt% MIL-53 demonstrated nearly 96% BSA rejection and around 86% MB rejection in the mixed foulant case (BSA-MB). The modified membrane exhibited a substantial increase in water flux from 176 L m<sup>-2</sup>.h<sup>-1</sup> to 327 L m<sup>-2</sup>.h<sup>-1</sup>. The findings of this research show the potential of iron-based MOFs in improving the performance of UF membranes and provide a platform for future studies on significant areas such as long-term stability studies and testing with other pollutants found in textile wastewater.

Authors

Institutions

Publication Details

Journal
Chemosphere
Published
2024-08-23
DOI
https://doi.org/10.1016/j.chemosphere.2024.143170
Citations
33
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
6.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microplastics and dye removal from textile wastewater using MIL-53 (Fe) metal-organic framework-based ultrafiltration membranes

Mohadeseh Najafi, Amir Razmjou, Javad Farahbakhsh, Masoumeh Zargar et al.
33 citations
Chemosphere
Membrane Separation Technologies
6.65
article

Microplastics and dye removal from textile wastewater using MIL-53 (Fe) metal-organic framework-based ultrafiltration membranes

Mohadeseh Najafi, Amir Razmjou, Javad Farahbakhsh, Masoumeh Zargar, Mitra Golgoli, Mehdi Khiadani, Abdul Hannan Asif
article en
33 citations

Abstract

Microplastics (MPs) and other organic matters in textile wastewater have posed a formidable challenge for treatment processes, particularly in the primary stages such as ultrafiltration (UF). UF plays a crucial role in preventing the entry of pollutants into subsequent treatment steps. However, the performance efficiency of UF membranes is compromised by the potential fouling of membrane pores by MPs, dyes and other organic pollutants such as bovine serum albumin (BSA). This study focuses on enhancing UF membrane performance, specifically its antifouling properties, through the development of high-performance membranes using MIL-53(Fe) metal-organic framework (MOF) particles (noted as MIL-53 here). Various concentrations of the MIL-53 (0.05, 0.1, 0.2, and 0.5 wt%) were integrated into the membrane structure through phase inversion process. Streaming zeta potential results confirmed the negatively charged surface of the membranes and their high hydrophilicity was validated through contact angle analysis. FTIR, SEM, EDS, and XRD confirmed the presence of MIL-53 particles on the surface of membranes. The developed membranes were tested for 24 h to assess their antifouling properties, with a subsequent 30-min hydraulic flush to measure their flux recovery ratios. Methylene Blue (MB) dye was used as a cationic dye present in textile wastewater to evaluate the efficiency of the developed membranes in dye removal and the synergistic effects of dye rejection in the presence of organic matters (i.e., MPs and BSA). Since previous studies have not fully addressed the combination of dyes and organic matter, this study thoroughly investigated the effect of particle-type foulants (MPs) and their interactions with dye (MB), as well as water soluble protein-type foulants (BSA) and their interaction with MB. The results indicated that the developed membranes exhibited higher MB rejection when the dye was present with either MP or BSA, along with improved antifouling properties. The optimised UF membrane integrated with 0.1 wt% MIL-53 demonstrated nearly 96% BSA rejection and around 86% MB rejection in the mixed foulant case (BSA-MB). The modified membrane exhibited a substantial increase in water flux from 176 L m<sup>-2</sup>.h<sup>-1</sup> to 327 L m<sup>-2</sup>.h<sup>-1</sup>. The findings of this research show the potential of iron-based MOFs in improving the performance of UF membranes and provide a platform for future studies on significant areas such as long-term stability studies and testing with other pollutants found in textile wastewater.

ChemosphereVol. 364
Edith Cowan University (AU)
AMP Foundation, Australian Research Council
Clean water and sanitation
Openalex Percentile: Top 2%
Membrane Separation Technologies
6.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.