Dual channel D-shaped SPR sensor for efficient detection of change in refractive index of analytes

Over the past ten years, significant advancements have been made in the field of D-shaped Surface Plasmon Resonance (SPR)-based optical fiber refractive index (RI) sensors which can be effectively used in chemical, biological, and health monitoring applications. Among single and dual/multi-channel SPR sensors, single-channel SPR sensors require analyte filling, emptying, and cleaning stages which is time-consuming and expensive. This work focuses on the design and performance investigation of a dual-channel D-shaped SPR sensor that can be used for the efficient detection of changes in the RI of analytes between two channels. The finite element method is used for the performance evaluation of the designed sensor, where the RI of the analyte of one channel is kept constant and that of the other channel is varied to observe the effect of change in RI difference from the known value. The proposed sensor can effectively detect the RI of analytes in the range of 1.33–1.40. The maximum wavelength and amplitude sensitivities are found to be 46000 nm/RIU and 6.96 RIU -1 , respectively. In addition, it exhibits comparable wavelength and amplitude resolutions of 1.30 × 10­ −05 RIU and 1.75 × 10 −08 RIU, respectively with asymmetrical RIs in two channels. Besides, the single-channel D-shaped SPR sensor having the same design parameters as the dual channel shows the maximum wavelength and amplitude sensitivities of 44000 nm/RIU and -59.22 RIU -1 , with wavelength and amplitude resolutions of 2.27 × 10 −6 RIU and 1.01 × 10 −09 RIU, respectively. Thus, the designed dual-channel D-shaped SPR sensor has the provision for determining the RI differences of analytes, which could be used to check the consistency of RI among different batches of analytes for the same biological sample.

Authors

Institutions

Publication Details

Journal
Optics Continuum
Published
2024-08-23
DOI
https://doi.org/10.1364/optcon.532535
Citations
5
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual channel D-shaped SPR sensor for efficient detection of change in refractive index of analytes

Md Jahirul Islam, Md Rejvi Kaysir, Sheikh Shahriar Hossain, Elora Nahid et al.
5 citations
Optics Continuum
Analytical Chemistry and Sensors
1.44
article

Dual channel D-shaped SPR sensor for efficient detection of change in refractive index of analytes

Md Jahirul Islam, Md Rejvi Kaysir, Sheikh Shahriar Hossain, Elora Nahid, Mohammad Shaifur Rahman
article en
5 citations

Abstract

Over the past ten years, significant advancements have been made in the field of D-shaped Surface Plasmon Resonance (SPR)-based optical fiber refractive index (RI) sensors which can be effectively used in chemical, biological, and health monitoring applications. Among single and dual/multi-channel SPR sensors, single-channel SPR sensors require analyte filling, emptying, and cleaning stages which is time-consuming and expensive. This work focuses on the design and performance investigation of a dual-channel D-shaped SPR sensor that can be used for the efficient detection of changes in the RI of analytes between two channels. The finite element method is used for the performance evaluation of the designed sensor, where the RI of the analyte of one channel is kept constant and that of the other channel is varied to observe the effect of change in RI difference from the known value. The proposed sensor can effectively detect the RI of analytes in the range of 1.33–1.40. The maximum wavelength and amplitude sensitivities are found to be 46000 nm/RIU and 6.96 RIU -1 , respectively. In addition, it exhibits comparable wavelength and amplitude resolutions of 1.30 × 10­ −05 RIU and 1.75 × 10 −08 RIU, respectively with asymmetrical RIs in two channels. Besides, the single-channel D-shaped SPR sensor having the same design parameters as the dual channel shows the maximum wavelength and amplitude sensitivities of 44000 nm/RIU and -59.22 RIU -1 , with wavelength and amplitude resolutions of 2.27 × 10 −6 RIU and 1.01 × 10 −09 RIU, respectively. Thus, the designed dual-channel D-shaped SPR sensor has the provision for determining the RI differences of analytes, which could be used to check the consistency of RI among different batches of analytes for the same biological sample.

Optics ContinuumVol. 3(9)
Photonics (United States) (US), Institute of Information and Communication Technologies (BG)
Affordable and clean energy
Openalex Percentile: Top 21%
Analytical Chemistry and Sensors
1.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.