Investigation of the Deionization Rate of Asymmetric Capacitive Deionization Technology for the Treatment of Short-Chain Perfluoroalkyl Substances (PFAS)

Objectives : This study aims to introduce and evaluate the effectiveness of asymmetric membrane capacitive deionization (ACDI) in removing short-chain perfluoroalkyl substances (PFAS), specifically perfluorobutane sulfonic acid (PFBS), from aqueous solutions. This study offers important insights for the advancement of CDI technology in the sustainable treatment of industrial wastewater containing PFAS.Methods : ACDI was employed by removing the anion exchange membrane from conventional membrane capacitive deionization system. The effect of key operational parameters such as voltage (0.5~1.2 V), initial concentration (50~500 mg/L), and flow rate (1~5 ml/min) on PFBS removal efficiency was systematically investigated. Additionally, PFBS removal performance in the presence of chloride ions was also investigated to determine competing ion effects.Results and Discussion : The ACDI system significantly outperformed both CDI and MCDI, achieving a maximum deionization rate of 0.032 mg/g/s, compared to 0.012 mg/g/s for CDI and 0.01 mg/g/s for MCDI. Increasing the applied voltage from 0.5 V to 1.2 V enhanced the deionization rate, with the highest rate observed at 1.2 V. Higher initial PFBS concentrations also improved the deionization rate, increasing from 0.0009 mg/g/s at 50 mg/L to 0.032 mg/g/s at 500 mg/L. The optimal flow rate was found to be 2 ml/min, balancing ion contact time and throughput, resulting in the highest deionization rate. The presence of competing ions, such as chloride, reduced PFBS removal efficiency, as shown by the decrease in deionization rate when NaCl was added to the feed solution.Conclusion : Overall, the ACDI system demonstrated superior deionization capacity and energy efficiency for PFBS removal, highlighting its potential as a sustainable and efficient technology for treating water contaminated with short-chain PFAS. Future research should address the challenges posed by competing ions in real-world wastewater to further optimize the ACDI system’s performance.

Authors

Publication Details

Journal
Journal of Korean Society of Environmental Engineers
Published
2024-08-23
DOI
https://doi.org/10.4491/ksee.2024.46.8.420
Citations
1
Primary Topic
Membrane-based Ion Separation Techniques
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Deionization Rate of Asymmetric Capacitive Deionization Technology for the Treatment of Short-Chain Perfluoroalkyl Substances (PFAS)

Hongsik Yoon, Taijin Min, SeongBeom Jeon, K. H. Ryu et al.
1 citations
Journal of Korean Society of Environmental Engineers
Membrane-based Ion Separation Techniques
0.18
article

Investigation of the Deionization Rate of Asymmetric Capacitive Deionization Technology for the Treatment of Short-Chain Perfluoroalkyl Substances (PFAS)

Hongsik Yoon, Taijin Min, SeongBeom Jeon, K. H. Ryu, Chung Kyu Lee, Jinhan Yun, Sungil Lim
article en
1 citations

Abstract

Objectives : This study aims to introduce and evaluate the effectiveness of asymmetric membrane capacitive deionization (ACDI) in removing short-chain perfluoroalkyl substances (PFAS), specifically perfluorobutane sulfonic acid (PFBS), from aqueous solutions. This study offers important insights for the advancement of CDI technology in the sustainable treatment of industrial wastewater containing PFAS.Methods : ACDI was employed by removing the anion exchange membrane from conventional membrane capacitive deionization system. The effect of key operational parameters such as voltage (0.5~1.2 V), initial concentration (50~500 mg/L), and flow rate (1~5 ml/min) on PFBS removal efficiency was systematically investigated. Additionally, PFBS removal performance in the presence of chloride ions was also investigated to determine competing ion effects.Results and Discussion : The ACDI system significantly outperformed both CDI and MCDI, achieving a maximum deionization rate of 0.032 mg/g/s, compared to 0.012 mg/g/s for CDI and 0.01 mg/g/s for MCDI. Increasing the applied voltage from 0.5 V to 1.2 V enhanced the deionization rate, with the highest rate observed at 1.2 V. Higher initial PFBS concentrations also improved the deionization rate, increasing from 0.0009 mg/g/s at 50 mg/L to 0.032 mg/g/s at 500 mg/L. The optimal flow rate was found to be 2 ml/min, balancing ion contact time and throughput, resulting in the highest deionization rate. The presence of competing ions, such as chloride, reduced PFBS removal efficiency, as shown by the decrease in deionization rate when NaCl was added to the feed solution.Conclusion : Overall, the ACDI system demonstrated superior deionization capacity and energy efficiency for PFBS removal, highlighting its potential as a sustainable and efficient technology for treating water contaminated with short-chain PFAS. Future research should address the challenges posed by competing ions in real-world wastewater to further optimize the ACDI system’s performance.

Journal of Korean Society of Environmental EngineersVol. 46(8)
Ministry of Environment, Korea Environmental Industry and Technology Institute
Openalex Percentile: Top 53%
Membrane-based Ion Separation Techniques
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.