Experimental full-volume airway approximation for assessing breath-dependent regional aerosol deposition

Modeling aerosol dynamics in the airways is challenging, and most modern personalized <i>in vitro</i> tools consider only a single inhalation maneuver through less than 10% of the total lung volume. Here, we present an <i>in vitro</i> modeling pipeline to produce a device that preserves patient-specific upper airways while approximating deeper airways, capable of achieving total lung volumes over 7 liters. The modular system, called TIDAL, includes tunable inhalation and exhalation breathing capabilities with resting flow rates up to 30 liters per minute. We show that the TIDAL system is easily coupled with industrially and clinically relevant devices for aerosol therapeutics. Using a vibrating mesh nebulizer, we report central-to-peripheral (C:P) aerosol deposition measurements aligned with both <i>in vivo</i> and <i>in silico</i> benchmarks. These findings underscore the effectiveness of the TIDAL model in predicting airway deposition dynamics for inhalable therapeutics.

Authors

Institutions

Publication Details

Journal
Device
Published
2024-08-23
DOI
https://doi.org/10.1016/j.device.2024.100514
Citations
6
Primary Topic
Inhalation and Respiratory Drug Delivery
Type
article
Field-Weighted Citation Impact
2.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental full-volume airway approximation for assessing breath-dependent regional aerosol deposition

Yinkui Yu, Catherine A. Fromen, Ian R. Woodward
6 citations
Device
Inhalation and Respiratory Drug Delivery
2.51
article

Experimental full-volume airway approximation for assessing breath-dependent regional aerosol deposition

Yinkui Yu, Catherine A. Fromen, Ian R. Woodward
article en
6 citations

Abstract

Modeling aerosol dynamics in the airways is challenging, and most modern personalized <i>in vitro</i> tools consider only a single inhalation maneuver through less than 10% of the total lung volume. Here, we present an <i>in vitro</i> modeling pipeline to produce a device that preserves patient-specific upper airways while approximating deeper airways, capable of achieving total lung volumes over 7 liters. The modular system, called TIDAL, includes tunable inhalation and exhalation breathing capabilities with resting flow rates up to 30 liters per minute. We show that the TIDAL system is easily coupled with industrially and clinically relevant devices for aerosol therapeutics. Using a vibrating mesh nebulizer, we report central-to-peripheral (C:P) aerosol deposition measurements aligned with both <i>in vivo</i> and <i>in silico</i> benchmarks. These findings underscore the effectiveness of the TIDAL model in predicting airway deposition dynamics for inhalable therapeutics.

DeviceVol. 2(12)
University of Delaware (US)
National Science Foundation, U.S. Department of Education, National Institutes of Health, National Institute of General Medical Sciences
Openalex Percentile: Top 10%
Inhalation and Respiratory Drug Delivery
2.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.