Novel Microwave Assisted-Hydrogen Peroxide Digestion of Coal and Fuel Oils Using Methionine as a Capping Reagent for the Determination of Mercury by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)

A novel analytical method was developed for quantifying total mercury in fuel oils using methionine as a capping reagent. Methionine was added to fuel and standard solutions as a preserving agent before microwave-assisted hydrogen peroxide digestion (MW-AHPD). To the best of our knowledge, it is the first-time methionine was used as a capping reagent for the total determination of mercury in fuel oils using ICP-OES with a pneumatic nebulizer. Multivariate optimization tools (two-level half factorial and central composite design) were used to investigate the most influential parameters of the MW-AHPD method. The best conditions were 0.1 g sample mass, 5 mol L−1 [H2O2], 5. 95 mol L−1 [methionine], 36 min and 200 °C with accepted trueness (93–107%) and precision (1.94%). The developed MW-AHPD procedure provided a coefficient of determination (R2) of 0.9989, limit of detection (LOD) of 0.25 µg L−1 and limit of quantification (LOQ) of 0.8 µg L−1. The newly developed MW-AHPD procedure was validated using hydride generation-ICP-OES and there was no statistical difference at 95% confidence level between the newly developed method and the standard protocol. Therefore, the newly developed MW-AHPD procedure was applied with coal, crude oil, gasoline, diesel oil, and kerosine samples and the concentration levels were from 0.876 ± 0.023 to 0.938 ± 0.082 µgg−1, 0.383 ± 0.043 to 0.506 ± 105 µgg−1, 0.306 ± 0.010 to 0.390 ± 0035 µgg−1, 0.360 ± 0.003 to 0.431 ± 0.001 µgg−1 and < DL, respectively.

Authors

Institutions

Publication Details

Journal
Analytical Letters
Published
2024-08-23
DOI
https://doi.org/10.1080/00032719.2024.2391872
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Microwave Assisted-Hydrogen Peroxide Digestion of Coal and Fuel Oils Using Methionine as a Capping Reagent for the Determination of Mercury by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)

Philiswa N. Nomngongo, Precious Nokwethemba Mahlambi, Nomvano Mketo, Mxolisi J Kiwanuka
1 citations
Analytical Letters
Analytical chemistry methods development
0.24
article

Novel Microwave Assisted-Hydrogen Peroxide Digestion of Coal and Fuel Oils Using Methionine as a Capping Reagent for the Determination of Mercury by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)

Philiswa N. Nomngongo, Precious Nokwethemba Mahlambi, Nomvano Mketo, Mxolisi J Kiwanuka
article en
1 citations

Abstract

A novel analytical method was developed for quantifying total mercury in fuel oils using methionine as a capping reagent. Methionine was added to fuel and standard solutions as a preserving agent before microwave-assisted hydrogen peroxide digestion (MW-AHPD). To the best of our knowledge, it is the first-time methionine was used as a capping reagent for the total determination of mercury in fuel oils using ICP-OES with a pneumatic nebulizer. Multivariate optimization tools (two-level half factorial and central composite design) were used to investigate the most influential parameters of the MW-AHPD method. The best conditions were 0.1 g sample mass, 5 mol L−1 [H2O2], 5. 95 mol L−1 [methionine], 36 min and 200 °C with accepted trueness (93–107%) and precision (1.94%). The developed MW-AHPD procedure provided a coefficient of determination (R2) of 0.9989, limit of detection (LOD) of 0.25 µg L−1 and limit of quantification (LOQ) of 0.8 µg L−1. The newly developed MW-AHPD procedure was validated using hydride generation-ICP-OES and there was no statistical difference at 95% confidence level between the newly developed method and the standard protocol. Therefore, the newly developed MW-AHPD procedure was applied with coal, crude oil, gasoline, diesel oil, and kerosine samples and the concentration levels were from 0.876 ± 0.023 to 0.938 ± 0.082 µgg−1, 0.383 ± 0.043 to 0.506 ± 105 µgg−1, 0.306 ± 0.010 to 0.390 ± 0035 µgg−1, 0.360 ± 0.003 to 0.431 ± 0.001 µgg−1 and < DL, respectively.

Analytical LettersVol. 58(10)
University of South Africa (ZA), University of Johannesburg (ZA), University of KwaZulu-Natal (ZA)
Openalex Percentile: Top 53%
Analytical chemistry methods development
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.