Electrochemical Acid–Base Transport Limitation Principle for Low Electroactive Analyte Sensing in Wastewater Monitoring

Electrochemical sensing (ES) is crucial for improving data acquisition in wastewater treatment, but obtaining the signal for a low electroactive analyte is challenging. Here, we propose an electrochemical acid-base transport limitation (eABTL) principle for inertness-based sensing, offering a new insight into generating ES signals from an interfacial transport process rather than electron transfer. This principle enables potential ES application for various weak acids and bases (WABs) without reactions themselves. We established an eABTL<sub>P</sub> method for detecting orthophosphate in solutions as a proof of concept, demonstrating commendable accuracy and precision, and a wide detection range from 10 μM to over 300 mM. Endogenous interferences were identified using 23 weak acids, indicating no significant endogenous interfering factors in typical wastewaters. Of them, volatile fatty acids are the main interference, but their effect can be eliminated by adjusting pH above 6.0. Exogenous factors like anions, cations, ion strength, temperature, organic load, and dissolved oxygen were examined, and most of their effects can be ignored by maintaining consistent analytical procedures between calibration curve and sample. Furthermore, measurement of wastewater samples confirmed the applicability toward domestic wastewater and demonstrated its wide applicability when combined with digestion pretreatment. Given the merits of inertness-based sensing, the eABTL-based methods have the potential to be a crucial part of ES techniques for environmental and industrial monitoring.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2024-08-23
DOI
https://doi.org/10.1021/acs.est.4c02949
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Acid–Base Transport Limitation Principle for Low Electroactive Analyte Sensing in Wastewater Monitoring

Ying Zhao, Xiaohui Yang, Zhaoming Chen, Fengjun Yin et al.
2 citations
Environmental Science & Technology
Analytical Chemistry and Sensors
0.58
article

Electrochemical Acid–Base Transport Limitation Principle for Low Electroactive Analyte Sensing in Wastewater Monitoring

Ying Zhao, Xiaohui Yang, Zhaoming Chen, Fengjun Yin, Shun Lu, Lin Chang, Hong Liu, Shuangshuang Liu
article en
2 citations

Abstract

Electrochemical sensing (ES) is crucial for improving data acquisition in wastewater treatment, but obtaining the signal for a low electroactive analyte is challenging. Here, we propose an electrochemical acid-base transport limitation (eABTL) principle for inertness-based sensing, offering a new insight into generating ES signals from an interfacial transport process rather than electron transfer. This principle enables potential ES application for various weak acids and bases (WABs) without reactions themselves. We established an eABTL<sub>P</sub> method for detecting orthophosphate in solutions as a proof of concept, demonstrating commendable accuracy and precision, and a wide detection range from 10 μM to over 300 mM. Endogenous interferences were identified using 23 weak acids, indicating no significant endogenous interfering factors in typical wastewaters. Of them, volatile fatty acids are the main interference, but their effect can be eliminated by adjusting pH above 6.0. Exogenous factors like anions, cations, ion strength, temperature, organic load, and dissolved oxygen were examined, and most of their effects can be ignored by maintaining consistent analytical procedures between calibration curve and sample. Furthermore, measurement of wastewater samples confirmed the applicability toward domestic wastewater and demonstrated its wide applicability when combined with digestion pretreatment. Given the merits of inertness-based sensing, the eABTL-based methods have the potential to be a crucial part of ES techniques for environmental and industrial monitoring.

Environmental Science & TechnologyVol. 58(42)
Chongqing Institute of Green and Intelligent Technology (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Youth Innovation Promotion Association of the Chinese Academy of Sciences
Clean water and sanitation
Openalex Percentile: Top 39%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.