Heparin-Bead Extraction Enhanced Fluorogenic Aptamer–Thrombin Composite Reporter Enables Sensitive and Rapid Detection of Functional Antithrombin

Antithrombin (AT) deficiency in the extracorporeal circulation during cardiac surgery leads to uncontrolled inflammation and vascular damage in patients. AT levels decrease in sepsis, major trauma, extracorporeal membrane oxygenation, and eclampsia. Monitoring plasma AT levels facilitates the accurate restoration of AT to baseline values through precise supplementation. Traditional methods of chromogenic assay and enzyme-linked immunosorbent assay (ELISA) kits encounter challenges, such as interference, inconsistency, and delayed response times, making real-time, reliable antithrombin monitoring a clinical gap. To address this critical need, we develop a heparin-bead extraction enhanced fluoroGenic aptamer-thrombin composite reporter (HExGATOR) for the rapid, sensitive, and precise detection of functional AT in plasma. Our design employs thrombin-binding aptamers and a fluorescence "turn on" technology such that a signal is produced upon the interaction of AT with the otherwise "turned off" aptamer-thrombin complex. The prominent signal-background interference originating from plasma is remarkably diminished by using a heparin-bead solid-phase extraction of AT. We achieved highly sensitive and rapid detection of AT in 5 to 20 min with a limit of detection of 15.11 nM. This approach offers a promising alternative to traditional AT tests in clinical settings, potentially facilitating personalized anticoagulant therapy.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-08-23
DOI
https://doi.org/10.1021/acssensors.4c01294
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heparin-Bead Extraction Enhanced Fluorogenic Aptamer–Thrombin Composite Reporter Enables Sensitive and Rapid Detection of Functional Antithrombin

Bruce D. Spiess, Weihong Tan, Adam S. Veige, Yong Zeng et al.
2 citations
ACS Sensors
Advanced biosensing and bioanalysis techniques
0.47
article

Heparin-Bead Extraction Enhanced Fluorogenic Aptamer–Thrombin Composite Reporter Enables Sensitive and Rapid Detection of Functional Antithrombin

Bruce D. Spiess, Weihong Tan, Adam S. Veige, Yong Zeng, Zimu Tian, He Yan, Emma Ziegenbein, Amanda Santana, Ying Liu
article en
2 citations

Abstract

Antithrombin (AT) deficiency in the extracorporeal circulation during cardiac surgery leads to uncontrolled inflammation and vascular damage in patients. AT levels decrease in sepsis, major trauma, extracorporeal membrane oxygenation, and eclampsia. Monitoring plasma AT levels facilitates the accurate restoration of AT to baseline values through precise supplementation. Traditional methods of chromogenic assay and enzyme-linked immunosorbent assay (ELISA) kits encounter challenges, such as interference, inconsistency, and delayed response times, making real-time, reliable antithrombin monitoring a clinical gap. To address this critical need, we develop a heparin-bead extraction enhanced fluoroGenic aptamer-thrombin composite reporter (HExGATOR) for the rapid, sensitive, and precise detection of functional AT in plasma. Our design employs thrombin-binding aptamers and a fluorescence "turn on" technology such that a signal is produced upon the interaction of AT with the otherwise "turned off" aptamer-thrombin complex. The prominent signal-background interference originating from plasma is remarkably diminished by using a heparin-bead solid-phase extraction of AT. We achieved highly sensitive and rapid detection of AT in 5 to 20 min with a limit of detection of 15.11 nM. This approach offers a promising alternative to traditional AT tests in clinical settings, potentially facilitating personalized anticoagulant therapy.

ACS SensorsVol. 9(9)
University of Florida Health (US), University of Florida (US), UF Health Cancer Center, Florida College (US)
Grifols, National Institutes of Health
Openalex Percentile: Top 36%
Advanced biosensing and bioanalysis techniques
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.