Compαrαtive chαrαcteristics of luminescent detector mαteriαls bαsed on α-Αl2O3-δ for neutron dosimetry

The optically stimulated luminescence (OSL) and the separation efficiency of the neutron and gamma components by OSL outputs were studied for samples of anion-deficient corundum (α-Αl2O3-δ) in ceramic and single-crystal forms with various neutron converters. For OSL dosimetry in mixed gamma-neutron fields, a detector material synthesized using ceramic technology consisting of a mixture of OSL active α-Αl2O3-δ and neutron-converter 6LiF powders in a ratio of 7:3 was selected as a promising one. The lower limit of the individual dose equivalent for such material under neutron irradiation does not exceed 30 μSv, and the dose dependence is linear up to 1 Sv.

Authors

Institutions

Publication Details

Journal
Дефектоскопия
Published
2024-08-23
DOI
https://doi.org/10.31857/s0130308224070064
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compαrαtive chαrαcteristics of luminescent detector mαteriαls bαsed on α-Αl2O3-δ for neutron dosimetry

Α. I. Surdo, I. I. Milman, R. M. Αbashev, Α. I. Boyarincev et al.
Дефектоскопия
Radiation Detection and Scintillator Technologies
article

Compαrαtive chαrαcteristics of luminescent detector mαteriαls bαsed on α-Αl2O3-δ for neutron dosimetry

Α. I. Surdo, I. I. Milman, R. M. Αbashev, Α. I. Boyarincev, Α. D. Petrakovich
article en

Abstract

The optically stimulated luminescence (OSL) and the separation efficiency of the neutron and gamma components by OSL outputs were studied for samples of anion-deficient corundum (α-Αl2O3-δ) in ceramic and single-crystal forms with various neutron converters. For OSL dosimetry in mixed gamma-neutron fields, a detector material synthesized using ceramic technology consisting of a mixture of OSL active α-Αl2O3-δ and neutron-converter 6LiF powders in a ratio of 7:3 was selected as a promising one. The lower limit of the individual dose equivalent for such material under neutron irradiation does not exceed 30 μSv, and the dose dependence is linear up to 1 Sv.

Дефектоскопия(7)
M.N. Mikheev Institute of Metal Physics (RU)
Openalex Percentile: Top 86%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.