Design and Characterization of a Wearable Inertial Measurement Unit

The utilization of inertial measurement units as wearable sensors is proliferating across various domains, such as health care, sports, and rehabilitation. This expansion has produced a market of devices tailored to accommodate very specific ranges of operational demands. Simultaneously, this growth is creating opportunities for the development of a new class of devices more oriented towards general-purpose use and capable of capturing both high-frequency signals for short-term, event-driven motion analysis and low-frequency signals for extended monitoring. For such a design, which combines flexibility and low cost, a rigorous evaluation of the device in terms of deviation, noise levels, and precision is essential. This evaluation is crucial for identifying potential improvements and refining the design accordingly, yet it is rarely addressed in the literature. This paper presents the development process of such a device. The results of the design process demonstrate acceptable performance in optimizing energy consumption and storage capacity while highlighting the most critical optimizations needed to advance the device towards the goal of a smart, general-purpose unit for human motion monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-21
DOI
https://doi.org/10.3390/s24165388
Citations
6
Primary Topic
Inertial Sensor and Navigation
Type
article
Field-Weighted Citation Impact
7.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Characterization of a Wearable Inertial Measurement Unit

Diego Álvarez, Juan C. Álvarez, Antonio M. López, Diego Valdés Tirado et al.
6 citations
Sensors
Inertial Sensor and Navigation
7.79
article

Design and Characterization of a Wearable Inertial Measurement Unit

Diego Álvarez, Juan C. Álvarez, Antonio M. López, Diego Valdés Tirado, Gonzalo García Carro
article en
6 citations

Abstract

The utilization of inertial measurement units as wearable sensors is proliferating across various domains, such as health care, sports, and rehabilitation. This expansion has produced a market of devices tailored to accommodate very specific ranges of operational demands. Simultaneously, this growth is creating opportunities for the development of a new class of devices more oriented towards general-purpose use and capable of capturing both high-frequency signals for short-term, event-driven motion analysis and low-frequency signals for extended monitoring. For such a design, which combines flexibility and low cost, a rigorous evaluation of the device in terms of deviation, noise levels, and precision is essential. This evaluation is crucial for identifying potential improvements and refining the design accordingly, yet it is rarely addressed in the literature. This paper presents the development process of such a device. The results of the design process demonstrate acceptable performance in optimizing energy consumption and storage capacity while highlighting the most critical optimizations needed to advance the device towards the goal of a smart, general-purpose unit for human motion monitoring.

SensorsVol. 24(16)
Universidad de Oviedo (ES)
Instituto de Salud Carlos III
Affordable and clean energy
Openalex Percentile: Top 3%
Inertial Sensor and Navigation
7.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.