Micro-WADA and balloon test occlusion for sacrifice of distal P2 aneurysm

Here we present a fusiform, partially thrombosed, previously ruptured aneurysm in the posterior cerebral artery that was treated with parent vessel sacrifice after a micro-WADA and micro-balloon test occlusion (video 1). These aneurysms pose treatment challenges due to their deep location, morphology, and potentially eloquent distal supply.1 2 Primary coiling, stent assisted coiling, or microsurgical clipping are often not viable options, whereas flow diversion, parent vessel sacrifice,3 or trapping with bypass are usually employed. Pharmacological provocative testing via a micro-WADA4 5 with or without a micro-balloon test occlusion is critical to establish whether the territory at risk has functional eloquence, although specific reports for using these techniques are limited. We describe the patient presentation, initial treatment attempt and failure, and our protocol for performing a micro-WADA/balloon test occlusion test. neurintsurg;18/1/301/V1F1V1Video 1 Micro wada for PCA aneurysm.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2024-08-23
DOI
https://doi.org/10.1136/jnis-2024-022058
Citations
1
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micro-WADA and balloon test occlusion for sacrifice of distal P2 aneurysm

Isaac Josh Abecassis, Robert Underwood, Sameer Saleem Tebha, Vishwanath Sagi et al.
1 citations
Journal of NeuroInterventional Surgery
Intracranial Aneurysms: Treatment and Complications
0.37
article

Micro-WADA and balloon test occlusion for sacrifice of distal P2 aneurysm

Isaac Josh Abecassis, Robert Underwood, Sameer Saleem Tebha, Vishwanath Sagi, Dale Ding, Robert M. Starke
article en
1 citations

Abstract

Here we present a fusiform, partially thrombosed, previously ruptured aneurysm in the posterior cerebral artery that was treated with parent vessel sacrifice after a micro-WADA and micro-balloon test occlusion (video 1). These aneurysms pose treatment challenges due to their deep location, morphology, and potentially eloquent distal supply.1 2 Primary coiling, stent assisted coiling, or microsurgical clipping are often not viable options, whereas flow diversion, parent vessel sacrifice,3 or trapping with bypass are usually employed. Pharmacological provocative testing via a micro-WADA4 5 with or without a micro-balloon test occlusion is critical to establish whether the territory at risk has functional eloquence, although specific reports for using these techniques are limited. We describe the patient presentation, initial treatment attempt and failure, and our protocol for performing a micro-WADA/balloon test occlusion test. neurintsurg;18/1/301/V1F1V1Video 1 Micro wada for PCA aneurysm.

Journal of NeuroInterventional SurgeryVol. 18(1)
University of Louisville (US), University of Miami (US), Neurological Surgery (US)
Life below water
Openalex Percentile: Top 36%
Intracranial Aneurysms: Treatment and Complications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Micro-WADA and balloon test occlusion for sacrifice of distal P2 aneurysm — Isaac Josh Abecassis, Robert Underwood, et al. · Journal of NeuroInterventional Surgery (2024) | TGRS Research Map | TGRS