Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction
Oxygen uptake (V˙O2) is an essential metric for evaluating cardiopulmonary health and athletic performance, which can barely be directly measured. Heart rate (HR) is a prominent physiological indicator correlated with V˙O2 and is often used for indirect V˙O2 prediction. This study investigates the impact of HR placement on V˙O2 prediction accuracy by analyzing HR data combined with the respiratory rate (RESP) and minute ventilation (V˙E) from three anatomical locations: the chest; arm; and wrist. Twenty-eight healthy adults participated in incremental and constant workload cycling tests at various intensities. Data on V˙O2, RESP, V˙E, and HR were collected and used to develop a neural network model for V˙O2 prediction. The influence of HR position on prediction accuracy was assessed via Bland-Altman plots, and model performance was evaluated by mean absolute error (MAE), coefficient of determination (R<sup>2</sup>), and mean absolute percentage error (MAPE). Our findings indicate that HR combined with RESP and V˙E (V˙O2HR+RESP+V˙E) produces the most accurate V˙O2 predictions (MAE: 165 mL/min, R<sup>2</sup>: 0.87, MAPE: 15.91%). Notably, as exercise intensity increases, the accuracy of V˙O2 prediction decreases, particularly within high-intensity exercise. The substitution of HR with different anatomical sites significantly impacts V˙O2 prediction accuracy, with wrist placement showing a more profound effect compared to arm placement. In conclusion, this study underscores the importance of considering HR placement in V˙O2 prediction models, with RESP and V˙E serving as effective compensatory factors. These findings contribute to refining indirect V˙O2 estimation methods, enhancing their predictive capabilities across different exercise intensities and anatomical placements.
Authors
- Junqiang Qiu (ORCID: https://orcid.org/0000-0001-8313-9216)
- Kuan Tao (ORCID: https://orcid.org/0000-0003-0363-9865)
- Junchao Yang
- Xiangxin Li (ORCID: https://orcid.org/0000-0001-7536-4093)
- LU Zhi-hui
- Haoqi Xu
Institutions
- Beijing Sport University (CN)
Publication Details
- Journal
- Sensors
- Published
- 2024-08-21
- DOI
- https://doi.org/10.3390/s24165412
- Citations
- 3
- Primary Topic
- Cardiovascular and exercise physiology
- Type
- article
- Field-Weighted Citation Impact
- 2.15
Funders
- National Key Research and Development Program of China
- Fundamental Research Funds for the Central Universities