Innovative Air-Preconditioning Method for Accurate Particulate Matter Sensing in Humid Environments

Smart cities rely on a network of sensors to gather real-time data on various environmental factors, including air quality. This paper addresses the challenges of improving the accuracy of low-cost particulate matter sensors (LCPMSs) which can be compromised by environmental conditions, such as high humidity, which is common in many urban areas. Such weather conditions often lead to the overestimation of particle counts due to hygroscopic particle growth, resulting in a potential public concern, although most of the detected particles consist of just water. The paper presents an innovative design for an indicative air-quality measuring station that integrates the particulate matter sensor with a preconditioning subsystem designed to mitigate the impact of humidity. The preconditioning subsystem works by heating the incoming air, effectively reducing the relative humidity and preventing the hygroscopic growth of particles before they reach the sensor. To validate the effectiveness of this approach, parallel measurements were conducted using both preconditioned and non-preconditioned sensors over a period of 19 weeks. The data were analyzed to compare the performance of the sensors in terms of accuracy for PM<sub>1</sub>, PM<sub>2.5</sub>, and PM<sub>10</sub> particles. The results demonstrated a significant improvement in measurement accuracy for the preconditioned sensor, especially in environments with high relative humidity. When the conditions were too severe and both sensors started measuring incorrect values, the preconditioned sensor-measured values were closer to the actual values. Also, the period of measuring incorrect values was shorter with the preconditioned sensor. The results suggest that the implementation of air preconditioning subsystems in LCPMSs deployed in smart cities can provide a cost-effective solution to overcome humidity-related inaccuracies, thereby improving the overall quality of measured air pollution data.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-23
DOI
https://doi.org/10.3390/s24175477
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative Air-Preconditioning Method for Accurate Particulate Matter Sensing in Humid Environments

Leo Mršić, Zdravko Kunić, Goran Đambić, Tomislav Ražov
Sensors
Air Quality Monitoring and Forecasting
article

Innovative Air-Preconditioning Method for Accurate Particulate Matter Sensing in Humid Environments

Leo Mršić, Zdravko Kunić, Goran Đambić, Tomislav Ražov
article en

Abstract

Smart cities rely on a network of sensors to gather real-time data on various environmental factors, including air quality. This paper addresses the challenges of improving the accuracy of low-cost particulate matter sensors (LCPMSs) which can be compromised by environmental conditions, such as high humidity, which is common in many urban areas. Such weather conditions often lead to the overestimation of particle counts due to hygroscopic particle growth, resulting in a potential public concern, although most of the detected particles consist of just water. The paper presents an innovative design for an indicative air-quality measuring station that integrates the particulate matter sensor with a preconditioning subsystem designed to mitigate the impact of humidity. The preconditioning subsystem works by heating the incoming air, effectively reducing the relative humidity and preventing the hygroscopic growth of particles before they reach the sensor. To validate the effectiveness of this approach, parallel measurements were conducted using both preconditioned and non-preconditioned sensors over a period of 19 weeks. The data were analyzed to compare the performance of the sensors in terms of accuracy for PM<sub>1</sub>, PM<sub>2.5</sub>, and PM<sub>10</sub> particles. The results demonstrated a significant improvement in measurement accuracy for the preconditioned sensor, especially in environments with high relative humidity. When the conditions were too severe and both sensors started measuring incorrect values, the preconditioned sensor-measured values were closer to the actual values. Also, the period of measuring incorrect values was shorter with the preconditioned sensor. The results suggest that the implementation of air preconditioning subsystems in LCPMSs deployed in smart cities can provide a cost-effective solution to overcome humidity-related inaccuracies, thereby improving the overall quality of measured air pollution data.

SensorsVol. 24(17)
Higher Education Centre Novo Mesto (SI), Algebra Bernays University (HR)
Sustainable cities and communities
Openalex Percentile: Top 88%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.