Influence of Field Sampling Methods on Measuring Volatile Organic Compounds in a Swine Facility Using SUMMA Canisters

Volatile organic compounds (VOCs) play a crucial role in emission control, being one of the most important sources of odor while also serving as significant precursors to secondary organic aerosols and ozone formation. Appropriate sampling methods are essential for accurately assessing the concentration and composition of VOCs within swine barns. In this study, the effects of both passive air sampling and active air sampling on VOCs were evaluated, and the influence of storage time on the VOC stability in sampling canisters for both methods was investigated. SUMMA canisters, which are electropolished and passivated with silanization, offer excellent corrosion protection and resistance to high pressure and temperature and were used in this study. The predominant component categories prevailing within the pig house were found to be oxygenated VOCs (OVOCs) and volatile sulfur compounds (VSCs), with ethanol emerging as the most abundant component of VOCs detected. Notably, the statistical analysis results revealed no significant differences between passive and active sampling regarding the impact of storage time on substance concentration. Changes in canister pressure also did not significantly affect substance stability. The results showed that the C2–C3 compounds remained relatively stable, especially within 3 days, with recoveries above 80% within 20 days. Methyl sulfide, dimethyl disulfide, and ethanol were more stable within the first week, but their recoveries significantly dropped by day 20, with methyl sulfide and dimethyl disulfide at 62.3% and 65.3%, respectively. This study contributes to the development of a foundation for selecting appropriate VOC sampling methods in swine facilities for conducting a rational analysis of VOC samples.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2024-08-23
DOI
https://doi.org/10.3390/atmos15091021
Citations
4
Primary Topic
Odor and Emission Control Technologies
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Field Sampling Methods on Measuring Volatile Organic Compounds in a Swine Facility Using SUMMA Canisters

Lei Yu, Xiaoshuai Wang, Xin Li, Feng Li et al.
4 citations
Atmosphere
Odor and Emission Control Technologies
0.71
article

Influence of Field Sampling Methods on Measuring Volatile Organic Compounds in a Swine Facility Using SUMMA Canisters

Lei Yu, Xiaoshuai Wang, Xin Li, Feng Li, Qinqin Sun, Kaiying Wang
article en
4 citations

Abstract

Volatile organic compounds (VOCs) play a crucial role in emission control, being one of the most important sources of odor while also serving as significant precursors to secondary organic aerosols and ozone formation. Appropriate sampling methods are essential for accurately assessing the concentration and composition of VOCs within swine barns. In this study, the effects of both passive air sampling and active air sampling on VOCs were evaluated, and the influence of storage time on the VOC stability in sampling canisters for both methods was investigated. SUMMA canisters, which are electropolished and passivated with silanization, offer excellent corrosion protection and resistance to high pressure and temperature and were used in this study. The predominant component categories prevailing within the pig house were found to be oxygenated VOCs (OVOCs) and volatile sulfur compounds (VSCs), with ethanol emerging as the most abundant component of VOCs detected. Notably, the statistical analysis results revealed no significant differences between passive and active sampling regarding the impact of storage time on substance concentration. Changes in canister pressure also did not significantly affect substance stability. The results showed that the C2–C3 compounds remained relatively stable, especially within 3 days, with recoveries above 80% within 20 days. Methyl sulfide, dimethyl disulfide, and ethanol were more stable within the first week, but their recoveries significantly dropped by day 20, with methyl sulfide and dimethyl disulfide at 62.3% and 65.3%, respectively. This study contributes to the development of a foundation for selecting appropriate VOC sampling methods in swine facilities for conducting a rational analysis of VOC samples.

AtmosphereVol. 15(9)
Zhejiang Environmental Monitoring Center (CN), Zhejiang University (CN)
National Key Research and Development Program of China
Clean water and sanitation
Openalex Percentile: Top 39%
Odor and Emission Control Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.