Investigation on the Effects of Assembly Gaps in the Resonant Cavity of Klystrons

During the test of an S-band multibeam klystron (MBK) resonant cavity, an interesting experimental phenomenon was observed: the measured ohmic quality factor (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula>) of the cavity was surprisingly low (around 200, design value of 5090). This prompted an in-depth investigation, revealing that the low <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula> was due to the presence of a small gap on the perimeter of the resonant cavity, which resulted from an inadvertent mechanical design. The topology of this assembly gap was similar to an extremely thin coaxial line. To further investigate the impact of such assembly gap, theoretical and numerical models were developed to quantitatively analyze the effect of concentric/eccentric assembly gap on the cavity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula>, field asymmetry, the shunt impedance, mode competition, etc. The analysis indicates that the primary factor affecting <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula> is the length of the small gap. The concentricity and width mainly influence the symmetry and shunt impedance, respectively. The analysis showed good agreement with the experimental results. Based on the above findings, a new approach was proposed to conveniently reduce the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula> of the resonant cavity via employing an appropriately long, relatively narrow gap (1/1000 of its radii, to ensure concentricity even in the worst scenario), thereby facilitating the development of broadband klystrons.

Authors

Institutions

Publication Details

Journal
IEEE Electron Device Letters
Published
2024-08-23
DOI
https://doi.org/10.1109/led.2024.3448452
Citations
4
Primary Topic
Gyrotron and Vacuum Electronics Research
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on the Effects of Assembly Gaps in the Resonant Cavity of Klystrons

X. K. Zhang, Jin Xu, Pengcheng Yin, Hairong Yin et al.
4 citations
IEEE Electron Device Letters
Gyrotron and Vacuum Electronics Research
1.35
article

Investigation on the Effects of Assembly Gaps in the Resonant Cavity of Klystrons

X. K. Zhang, Jin Xu, Pengcheng Yin, Hairong Yin, Yanyu Wei, Jinchi Cai, Long Zeng, Lingna Yue, Zixuan Su, Jian Zhang, Yong Xu, Guohui Zhao, D.C. Chen, Wenxiang Wang, Chi Zhang
article en
4 citations

Abstract

During the test of an S-band multibeam klystron (MBK) resonant cavity, an interesting experimental phenomenon was observed: the measured ohmic quality factor (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula>) of the cavity was surprisingly low (around 200, design value of 5090). This prompted an in-depth investigation, revealing that the low <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula> was due to the presence of a small gap on the perimeter of the resonant cavity, which resulted from an inadvertent mechanical design. The topology of this assembly gap was similar to an extremely thin coaxial line. To further investigate the impact of such assembly gap, theoretical and numerical models were developed to quantitatively analyze the effect of concentric/eccentric assembly gap on the cavity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula>, field asymmetry, the shunt impedance, mode competition, etc. The analysis indicates that the primary factor affecting <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula> is the length of the small gap. The concentricity and width mainly influence the symmetry and shunt impedance, respectively. The analysis showed good agreement with the experimental results. Based on the above findings, a new approach was proposed to conveniently reduce the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${Q}_{{0}}$ </tex-math></inline-formula> of the resonant cavity via employing an appropriately long, relatively narrow gap (1/1000 of its radii, to ensure concentricity even in the worst scenario), thereby facilitating the development of broadband klystrons.

IEEE Electron Device LettersVol. 45(10)
University of Electronic Science and Technology of China (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 20%
Gyrotron and Vacuum Electronics Research
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.