Resilient Self-Triggered Model Predictive Control of Cyber-Physical Systems Under Two-Channel False Data Injection Attacks

Abstract This paper presents a novel resilient self-triggered model predictive control (ST-MPC) method to alleviate potential threats of false data injection (FDI) attacks on cyber-physical systems (CPSs). First, considering that the data transmitted via the sensor-to-controller (S–C) and controller-to-actuator (C–A) channels in CPS may be tampered with by FDI attacks, a novel input reconstruction strategy combined with the ST-MPC mechanism is proposed to alleviate the threats of FDI attacks while reducing the computational and communication resources, in which key optimal control signals are selected and protected based on systematic performance inequalities. Correspondingly, a resilient ST-MPC algorithm combined with the dual-mode strategy is further proposed. Moreover, the iterative feasibility and the closed-loop stability are strictly demonstrated. Finally, the effectiveness of the proposed strategy is verified via a simulation study.

Authors

Institutions

Publication Details

Journal
Journal of Dynamic Systems Measurement and Control
Published
2024-08-23
DOI
https://doi.org/10.1115/1.4066316
Citations
2
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilient Self-Triggered Model Predictive Control of Cyber-Physical Systems Under Two-Channel False Data Injection Attacks

Fuan Cheng, Ning He, Yi Chen, Yuxiang Li
2 citations
Journal of Dynamic Systems Measurement and Control
Smart Grid Security and Resilience
0.66
article

Resilient Self-Triggered Model Predictive Control of Cyber-Physical Systems Under Two-Channel False Data Injection Attacks

Fuan Cheng, Ning He, Yi Chen, Yuxiang Li
article en
2 citations

Abstract

Abstract This paper presents a novel resilient self-triggered model predictive control (ST-MPC) method to alleviate potential threats of false data injection (FDI) attacks on cyber-physical systems (CPSs). First, considering that the data transmitted via the sensor-to-controller (S–C) and controller-to-actuator (C–A) channels in CPS may be tampered with by FDI attacks, a novel input reconstruction strategy combined with the ST-MPC mechanism is proposed to alleviate the threats of FDI attacks while reducing the computational and communication resources, in which key optimal control signals are selected and protected based on systematic performance inequalities. Correspondingly, a resilient ST-MPC algorithm combined with the dual-mode strategy is further proposed. Moreover, the iterative feasibility and the closed-loop stability are strictly demonstrated. Finally, the effectiveness of the proposed strategy is verified via a simulation study.

Journal of Dynamic Systems Measurement and ControlVol. 147(2)
Xi'an University of Architecture and Technology (CN)
Ministry of Science and Technology of the People's Republic of China, Natural Science Foundation of Shaanxi Province
Openalex Percentile: Top 31%
Smart Grid Security and Resilience
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Resilient Self-Triggered Model Predictive Control of Cyber-Physical Systems Under Two-Channel False Data Injection Attacks — Fuan Cheng, Ning He, et al. · Journal of Dynamic Systems Measurement and Control (2024) | TGRS Research Map | TGRS