Development of a mechanical characterisation device for intracranial aneurysms: Calibration on polymeric phantom arteries

Intracranial aneurysm is a major health issue related to biomechanical arterial wall degradation. Currently, no method allows predicting rupture risk based on in vivo quantitative mechanical data. This work is part of a large-scale project aimed at providing clinicians with a non-invasive patient-specific decision support tool, based on the in vivo mechanical characterisation of the aneurysm wall. Thus, the primary objective of the project was to develop a deformation device prototype (DDP) of the artery wall and to calibrate it on polymeric phantom arteries. The deformations induced on the phantom arteries were quantified experimentally using a Digital Image Correlation (DIC) system. The results indicated that the DIC system was able to measure the small displacements generated by the DDP. We also observed that the flow mimicking the blood flow did not significantly disturb the measurements of the artery wall displacement caused by the DDP. Finally, a limit displacement value generated by the DDP was evaluated. This value corresponds to the lowest displacement value detectable by the clinical imaging system that will be tested on animals in the future (Spectral Photon Counting CT).

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2024-08-20
DOI
https://doi.org/10.1016/j.medengphy.2024.104225
Citations
1
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a mechanical characterisation device for intracranial aneurysms: Calibration on polymeric phantom arteries

C. Pailler‐Mattei, Hélène Magoariec, Jolan Raviol, G. Plet
1 citations
Medical Engineering & Physics
Intracranial Aneurysms: Treatment and Complications
0.37
article

Development of a mechanical characterisation device for intracranial aneurysms: Calibration on polymeric phantom arteries

C. Pailler‐Mattei, Hélène Magoariec, Jolan Raviol, G. Plet
article en
1 citations

Abstract

Intracranial aneurysm is a major health issue related to biomechanical arterial wall degradation. Currently, no method allows predicting rupture risk based on in vivo quantitative mechanical data. This work is part of a large-scale project aimed at providing clinicians with a non-invasive patient-specific decision support tool, based on the in vivo mechanical characterisation of the aneurysm wall. Thus, the primary objective of the project was to develop a deformation device prototype (DDP) of the artery wall and to calibrate it on polymeric phantom arteries. The deformations induced on the phantom arteries were quantified experimentally using a Digital Image Correlation (DIC) system. The results indicated that the DIC system was able to measure the small displacements generated by the DDP. We also observed that the flow mimicking the blood flow did not significantly disturb the measurements of the artery wall displacement caused by the DDP. Finally, a limit displacement value generated by the DDP was evaluated. This value corresponds to the lowest displacement value detectable by the clinical imaging system that will be tested on animals in the future (Spectral Photon Counting CT).

Medical Engineering & PhysicsVol. 131(1)
Université Claude Bernard Lyon 1 (FR), École Centrale de Lyon (FR), Centre National de la Recherche Scientifique (FR), Laboratoire de Tribologie et Dynamique des Systèmes (FR)
Région Auvergne-Rhône-Alpes
Openalex Percentile: Top 36%
Intracranial Aneurysms: Treatment and Complications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a mechanical characterisation device for intracranial aneurysms: Calibration on polymeric phantom arteries — C. Pailler‐Mattei, Hélène Magoariec, et al. · Medical Engineering & Physics (2024) | TGRS Research Map | TGRS