Non-homogeneous model for studying femur bone implants with considering defects

In this article, the natural frequencies of the femur in the presence and absence of defects have been calculated. For this purpose, two approaches to bone modeling have been considered: one for the homogeneous case and the other for the non-homogeneous case, which more closely reflects the reality of the femur bone. In the next step, in order to identify suitable materials for femur bone implants, two materials AZ31 and CP Ti have been selected, and the natural frequencies of the femur made with these two materials have been calculated and compared with the results of the natural femur. From the obtained results, it can be concluded that although these two materials are attractive for bone implants from other aspects, they are not approved from the point of view of vibrations, although material AZ31 is a little better. It is also observed that the selected defect in the femur has little effect on the natural frequencies.

Authors

Institutions

Publication Details

Journal
International Journal of Modelling and Simulation
Published
2024-08-21
DOI
https://doi.org/10.1080/02286203.2024.2392217
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-homogeneous model for studying femur bone implants with considering defects

Saleh Mobasseri, Maziar Janghorban
International Journal of Modelling and Simulation
Orthopaedic implants and arthroplasty
article

Non-homogeneous model for studying femur bone implants with considering defects

Saleh Mobasseri, Maziar Janghorban
article en

Abstract

In this article, the natural frequencies of the femur in the presence and absence of defects have been calculated. For this purpose, two approaches to bone modeling have been considered: one for the homogeneous case and the other for the non-homogeneous case, which more closely reflects the reality of the femur bone. In the next step, in order to identify suitable materials for femur bone implants, two materials AZ31 and CP Ti have been selected, and the natural frequencies of the femur made with these two materials have been calculated and compared with the results of the natural femur. From the obtained results, it can be concluded that although these two materials are attractive for bone implants from other aspects, they are not approved from the point of view of vibrations, although material AZ31 is a little better. It is also observed that the selected defect in the femur has little effect on the natural frequencies.

International Journal of Modelling and Simulation
Islamic Azad University, Marvdasht (IR)
Openalex Percentile: Top 75%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.