Clinical Factors That Influence Repeat<sup>68</sup>Ga-PSMA-11 PET/CT Scan Positivity in Patients with Recurrent Prostate Cancer Under Observation After a Negative<sup>68</sup>Ga-PSMA-11 PET/CT Scan: A Single-Center Retrospective Study

This analysis aimed to identify clinical factors associated with positivity on repeat <sup>68</sup>Ga-PSMA-11 PET/CT after a negative scan in patients with recurrent prostate cancer (PCa) under observation. <b>Methods:</b> This single-center, retrospective analysis included patients who underwent at least 2 <sup>68</sup>Ga-PSMA-11 PET/CT scans (PET1 and PET2) at UCLA between October 2016 and June 2021 for recurrent PCa with negative PET1 and no PCa-related treatments between the 2 scans. Using Prostate Cancer Molecular Imaging Standardized Evaluation criteria to define negative and positive scans, the final cohort was divided into PET2-negative (PET2-Neg) and PET2-positive (PET2-Pos). The same PET1 was used twice in the more than 2 PET cases with inclusion criteria fulfilled. Patient characteristics and clinical parameters were compared between the 2 cohorts using Mann-Whitney <i>U</i> test and Fisher exact test. Areas under the curve (AUCs) of the receiver operating characteristic and the Youden index were computed to determine the discrimination ability of statistically significant factors and specific cut points that maximized sensitivity and specificity, respectively. <b>Results:</b> The final analysis included 83 sets of 2 PET/CT scans from 70 patients. Thirty-nine of 83 (47%) sets were PET2-Neg, and 44 of 83 (53%) sets were PET2-Pos. Prostate-specific antigen (PSA) increased from PET1 to PET2 for all 83 (100%) sets of scans. Median PSA at PET1 was 0.4 ng/mL (interquartile range, 0.2-1.0) and at PET2 was 1.6 ng/mL (interquartile range, 0.9-3.8). We found higher serum PSA at PET2 (median, 1.8 vs. 1.1 ng/mL; <i>P</i> = 0.015), absolute PSA difference (median, 1.4 vs. 0.7 ng/mL; <i>P</i> = 0.006), percentage of PSA change (median, +270.4% vs. +150.0%: <i>P</i> = 0.031), and median PSA velocity (0.044 vs. 0.017 ng/mL/wk, <i>P</i> = 0.002) and shorter PSA doubling time (DT; median, 5.1 vs. 8.3 mo; <i>P</i> = 0.006) in the PET2-Pos cohort than in the PET2-Neg cohort. Receiver operating characteristic curves showed cutoffs for PSA at PET2 of 4.80 ng/mL (sensitivity, 34%; specificity, 92%; AUC, 0.66), absolute PSA difference of 0.95 ng/mL (sensitivity, 62%; specificity, 71%; AUC, 0.68), percentage of PSA change of a positive 289.50% (sensitivity, 48%; specificity, 82%; AUC, 0.64), PSA velocity of 0.033 ng/mL/wk (sensitivity, 57%; specificity, 80%; AUC, 0.70), and PSA DT of 7.91 mo (sensitivity, 71%; specificity, 62%; AUC, 0.67). <b>Conclusion:</b> Patients with recurrent PCa under observation after a negative <sup>68</sup>Ga-PSMA-11 PET/CT scan with markedly elevated serum PSA levels and shorter PSA DT are more likely to have positive findings on repeat <sup>68</sup>Ga-PSMA-11 PET/CT.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine
Published
2024-08-21
DOI
https://doi.org/10.2967/jnumed.124.267591
Citations
3
Primary Topic
Prostate Cancer Treatment and Research
Type
article
Field-Weighted Citation Impact
1.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Factors That Influence Repeat68Ga-PSMA-11 PET/CT Scan Positivity in Patients with Recurrent Prostate Cancer Under Observation After a Negative68Ga-PSMA-11 PET/CT Scan: A Single-Center Retrospective Study

Andrei Gafita, Jérémie Calais, Johannes Czernin, Ida Sonni et al.
3 citations
Journal of Nuclear Medicine
Prostate Cancer Treatment and Research
1.26
article

Clinical Factors That Influence Repeat68Ga-PSMA-11 PET/CT Scan Positivity in Patients with Recurrent Prostate Cancer Under Observation After a Negative68Ga-PSMA-11 PET/CT Scan: A Single-Center Retrospective Study

Andrei Gafita, Jérémie Calais, Johannes Czernin, Ida Sonni, Pan Thin, Masatoshi Hotta, Tristan Grogan
article en
3 citations

Abstract

This analysis aimed to identify clinical factors associated with positivity on repeat <sup>68</sup>Ga-PSMA-11 PET/CT after a negative scan in patients with recurrent prostate cancer (PCa) under observation. <b>Methods:</b> This single-center, retrospective analysis included patients who underwent at least 2 <sup>68</sup>Ga-PSMA-11 PET/CT scans (PET1 and PET2) at UCLA between October 2016 and June 2021 for recurrent PCa with negative PET1 and no PCa-related treatments between the 2 scans. Using Prostate Cancer Molecular Imaging Standardized Evaluation criteria to define negative and positive scans, the final cohort was divided into PET2-negative (PET2-Neg) and PET2-positive (PET2-Pos). The same PET1 was used twice in the more than 2 PET cases with inclusion criteria fulfilled. Patient characteristics and clinical parameters were compared between the 2 cohorts using Mann-Whitney <i>U</i> test and Fisher exact test. Areas under the curve (AUCs) of the receiver operating characteristic and the Youden index were computed to determine the discrimination ability of statistically significant factors and specific cut points that maximized sensitivity and specificity, respectively. <b>Results:</b> The final analysis included 83 sets of 2 PET/CT scans from 70 patients. Thirty-nine of 83 (47%) sets were PET2-Neg, and 44 of 83 (53%) sets were PET2-Pos. Prostate-specific antigen (PSA) increased from PET1 to PET2 for all 83 (100%) sets of scans. Median PSA at PET1 was 0.4 ng/mL (interquartile range, 0.2-1.0) and at PET2 was 1.6 ng/mL (interquartile range, 0.9-3.8). We found higher serum PSA at PET2 (median, 1.8 vs. 1.1 ng/mL; <i>P</i> = 0.015), absolute PSA difference (median, 1.4 vs. 0.7 ng/mL; <i>P</i> = 0.006), percentage of PSA change (median, +270.4% vs. +150.0%: <i>P</i> = 0.031), and median PSA velocity (0.044 vs. 0.017 ng/mL/wk, <i>P</i> = 0.002) and shorter PSA doubling time (DT; median, 5.1 vs. 8.3 mo; <i>P</i> = 0.006) in the PET2-Pos cohort than in the PET2-Neg cohort. Receiver operating characteristic curves showed cutoffs for PSA at PET2 of 4.80 ng/mL (sensitivity, 34%; specificity, 92%; AUC, 0.66), absolute PSA difference of 0.95 ng/mL (sensitivity, 62%; specificity, 71%; AUC, 0.68), percentage of PSA change of a positive 289.50% (sensitivity, 48%; specificity, 82%; AUC, 0.64), PSA velocity of 0.033 ng/mL/wk (sensitivity, 57%; specificity, 80%; AUC, 0.70), and PSA DT of 7.91 mo (sensitivity, 71%; specificity, 62%; AUC, 0.67). <b>Conclusion:</b> Patients with recurrent PCa under observation after a negative <sup>68</sup>Ga-PSMA-11 PET/CT scan with markedly elevated serum PSA levels and shorter PSA DT are more likely to have positive findings on repeat <sup>68</sup>Ga-PSMA-11 PET/CT.

Journal of Nuclear MedicineVol. 65(10)
University of California, Los Angeles (US), UCLA Medical Center (US), Magna Graecia University (IT), Molecular Theranostics (United States) (US), Western University of Health Sciences (US)
Good health and well-being
Openalex Percentile: Top 19%
Prostate Cancer Treatment and Research
1.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.