Battle of the Gases: How Air and Nitrous Oxide Affect Endotracheal Tube Cuff Pressure During General Anesthesia

Background Endotracheal tube (ETT) cuff pressure changes during general anesthesia. Endotracheal cuff pressure ideally should be maintained between 20 and 30 cm of H<sub>2</sub>O. Cuff pressure of less than 25 cm of H<sub>2</sub>O increases the chances of aspiration while pressure of more than 40 cm of H<sub>2</sub>O causes tracheal mucosa damage. The study aimed to monitor and compare variations of endotracheal cuff pressure during general anesthesia with oxygen-air or oxygen-nitrous oxide. Methods This prospective, randomized, double-blinded, observational study was conducted on 40 patients. After approval from the institutional ethics subcommittee, 40 patients of either gender, aged 18-60 years, belonging to ASA grades I and II, who were undergoing elective surgery under general anesthesia, were enrolled in this study. The patients were randomly divided into two groups, with 20 in each group. In Group A, oxygen-air and Group N, oxygen-nitrous oxide was used as a gaseous mixture in general anesthesia with ETT. The ETT cuff pressure was recorded with the help of a cuff manometer at intervals of five, 10, 20, 30, 40, 50, 60, 70, 80, and 90 minutes after intubation. If pressure was more than 40 cm of H<sub>2</sub>O, it was reduced to 25-30 cm of H<sub>2</sub>O. Data were collected and analyzed using methods described in Primer of Biostatistics by Stanton A. Glantz. Quantitative data were analyzed using the Student's t-test. Qualitative data were analyzed using the chi-square test. Results An increase in cuff pressure was noted more in Group N as compared to Group A. The pressure in the endotracheal cuff started to gradually increase after 30-40 minutes in Group N after intubation, while in Group A, there was no significant increase. The average number of times the cuff deflated was 0.2 ± 0.41 in Group A and 1.55 ± 0.51 in Group N, which was highly significant. Conclusion Changes in endotracheal cuff pressure were observed when using different gas mixtures for inflation. Specifically, cuff pressure increased with oxygen and nitrous oxide compared to oxygen with air. This suggests that anesthetic gas composition can impact cuff pressure, potentially affecting tracheal mucosal perfusion and patient safety. Therefore, regular monitoring and adjustment of cuff pressure is crucial, especially when using nitrous oxide, to prevent complications and ensure optimal patient care.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-08-21
DOI
https://doi.org/10.7759/cureus.67367
Citations
1
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Battle of the Gases: How Air and Nitrous Oxide Affect Endotracheal Tube Cuff Pressure During General Anesthesia

Abhishek Raj, Shivangi Gaur, Chandrakala Singh, Amala Kale et al.
1 citations
Cureus
Airway Management and Intubation Techniques
0.64
article

Battle of the Gases: How Air and Nitrous Oxide Affect Endotracheal Tube Cuff Pressure During General Anesthesia

Abhishek Raj, Shivangi Gaur, Chandrakala Singh, Amala Kale, Aparna Bagle
article en
1 citations

Abstract

Background Endotracheal tube (ETT) cuff pressure changes during general anesthesia. Endotracheal cuff pressure ideally should be maintained between 20 and 30 cm of H<sub>2</sub>O. Cuff pressure of less than 25 cm of H<sub>2</sub>O increases the chances of aspiration while pressure of more than 40 cm of H<sub>2</sub>O causes tracheal mucosa damage. The study aimed to monitor and compare variations of endotracheal cuff pressure during general anesthesia with oxygen-air or oxygen-nitrous oxide. Methods This prospective, randomized, double-blinded, observational study was conducted on 40 patients. After approval from the institutional ethics subcommittee, 40 patients of either gender, aged 18-60 years, belonging to ASA grades I and II, who were undergoing elective surgery under general anesthesia, were enrolled in this study. The patients were randomly divided into two groups, with 20 in each group. In Group A, oxygen-air and Group N, oxygen-nitrous oxide was used as a gaseous mixture in general anesthesia with ETT. The ETT cuff pressure was recorded with the help of a cuff manometer at intervals of five, 10, 20, 30, 40, 50, 60, 70, 80, and 90 minutes after intubation. If pressure was more than 40 cm of H<sub>2</sub>O, it was reduced to 25-30 cm of H<sub>2</sub>O. Data were collected and analyzed using methods described in Primer of Biostatistics by Stanton A. Glantz. Quantitative data were analyzed using the Student's t-test. Qualitative data were analyzed using the chi-square test. Results An increase in cuff pressure was noted more in Group N as compared to Group A. The pressure in the endotracheal cuff started to gradually increase after 30-40 minutes in Group N after intubation, while in Group A, there was no significant increase. The average number of times the cuff deflated was 0.2 ± 0.41 in Group A and 1.55 ± 0.51 in Group N, which was highly significant. Conclusion Changes in endotracheal cuff pressure were observed when using different gas mixtures for inflation. Specifically, cuff pressure increased with oxygen and nitrous oxide compared to oxygen with air. This suggests that anesthetic gas composition can impact cuff pressure, potentially affecting tracheal mucosal perfusion and patient safety. Therefore, regular monitoring and adjustment of cuff pressure is crucial, especially when using nitrous oxide, to prevent complications and ensure optimal patient care.

CureusVol. 16(8)
Dr. D. Y. Patil Medical College, Hospital and Research Centre (IN), Dr. D.Y. Patil Vidyapeeth, Pune (IN), Bharati Vidyapeeth (Deemed to be University) (IN)
Openalex Percentile: Top 29%
Airway Management and Intubation Techniques
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.