The detection chain for Athena X-IFU: a status on the design and demonstrations

The X-ray Integral Field Unit (X-IFU) instrument is the high-resolution X-ray spectrometer of the ESA Athena X-ray Observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution requirement of 4 eV (3 eV design goal) up to 7 keV from 5" pixels, with a hexagonal field of view of 4' equivalent diameter. The main sensor array and its associated detection chain is one of the major functional chains of the X-IFU instrument, and is the main contributor to XIFU performance. CNES (Centre National d’Études Spatiales) is the prime contractor for the X-IFU and leads the project development and procurement aspects within the X-IFU Consortium; additional major partners of the main detection chain are NASA-GFSC, SRON, VTT, APC, NIST, IRAP, and IAP. The detection chain design for X-IFU has evolved in the past few years in order to secure the performances and development costs, in the frame of the New Athena mission. New TES pixels are implemented with slower time constant and a reduced sensitivity to magnetic field. The slower time constant directly allows an increase of the MUX factor and a reduction of the number of channels, together with the decrease of the number of proximity electronics boxes, or warm front end electronics (WFEE). The cryostat outer vessel temperature is now a 50 K thermal interface, cooled passively thanks to L-shaped thermal shield (L-grooves). This has a direct impact of the cryo-harness between the 4 K core interface and the WFEE interface. In the past years, we have performed early demonstration on the critical components in order to secure the detection chain design and performances. This paper presents the progress done on early demonstrations (warm electronics, cryo-harness breadboarding,...), while providing an update to the detection-chain design description.

Authors

Institutions

Publication Details

Published
2024-08-21
DOI
https://doi.org/10.1117/12.3020011
Citations
6
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The detection chain for Athena X-IFU: a status on the design and demonstrations

C. Macculi, Brian J. Jackson, Frank Brachet, S. R. Bandler et al.
6 citations
Nuclear Physics and Applications
3.65
article

The detection chain for Athena X-IFU: a status on the design and demonstrations

C. Macculi, Brian J. Jackson, Frank Brachet, S. R. Bandler, D. Prêle, R. den Hartog, J. A. Chervenak, J. van der Kuur, Samuel V. Hull, Sophie Beaumont, M. Kiviranta, J. Souček, W. B. Doriese, H. van Weers, Kazuhiro Sakai, E. Taralli, Joel N. Ullom, Paul van der Hulst, Nicholas A. Wakeham, A. Argan, C. D. Reintsema, Edoardo Cucchetti, S. J. Smith, Hervé Geoffray, D. Vaccaro, Phillipe Peille, Manuel González, Laurent Ravera, Yann Parot, Christophe Daniel, Céline Cénac-Morthe, M. S. Durkin, J. M. Adams
article en
6 citations

Abstract

The X-ray Integral Field Unit (X-IFU) instrument is the high-resolution X-ray spectrometer of the ESA Athena X-ray Observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution requirement of 4 eV (3 eV design goal) up to 7 keV from 5" pixels, with a hexagonal field of view of 4' equivalent diameter. The main sensor array and its associated detection chain is one of the major functional chains of the X-IFU instrument, and is the main contributor to XIFU performance. CNES (Centre National d’Études Spatiales) is the prime contractor for the X-IFU and leads the project development and procurement aspects within the X-IFU Consortium; additional major partners of the main detection chain are NASA-GFSC, SRON, VTT, APC, NIST, IRAP, and IAP. The detection chain design for X-IFU has evolved in the past few years in order to secure the performances and development costs, in the frame of the New Athena mission. New TES pixels are implemented with slower time constant and a reduced sensitivity to magnetic field. The slower time constant directly allows an increase of the MUX factor and a reduction of the number of channels, together with the decrease of the number of proximity electronics boxes, or warm front end electronics (WFEE). The cryostat outer vessel temperature is now a 50 K thermal interface, cooled passively thanks to L-shaped thermal shield (L-grooves). This has a direct impact of the cryo-harness between the 4 K core interface and the WFEE interface. In the past years, we have performed early demonstration on the critical components in order to secure the detection chain design and performances. This paper presents the progress done on early demonstrations (warm electronics, cryo-harness breadboarding,...), while providing an update to the detection-chain design description.

Goddard Space Flight Center (US), Centre National d'Études Spatiales (FR), Agence Parisienne du Climat (FR), Space Research Organisation Netherlands (NL), National Institute for Astrophysics (IT), VTT Technical Research Centre of Finland (FI)
Industry, innovation and infrastructure
Openalex Percentile: Top 7%
Nuclear Physics and Applications
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.