High‐Performance Single‐Phase Bi‐Directional Novel On‐Board Charger for Electric Vehicles

ABSTRACT The design and development of a 550 W non‐isolated single‐phase two‐stage level‐1 bidirectional on‐board battery charger (OBC) for electric vehicles (EVs) have been discussed in this article, which is also capable of supplying the utility grid's reactive power needs. There are two stages in this topology. The first stage consists of a full bridge bidirectional AC to DC converter, and the second stage consists of a half‐bridge bidirectional DC to DC converter with enhanced vehicle‐to‐vehicle (V2V) capabilities for emergency roadside charging assistance scenarios. In an emergency, if there is not a charging station nearby and the battery is dead, EVs can use this feature to charge from other EVs. It can also work like a regular vehicle‐to‐grid (V2G) or grid‐to‐vehicle (G2V) system. The suggested charging topology has a maximum efficiency of 99.09%, a power factor of 0.99, and a total harmonic distortion (THD) of 6.31%. MATLAB/Simulink is used to develop and simulate the suggested EV charger, and simulation results are compared with the other on‐board chargers in the literature.

Authors

Institutions

Publication Details

Journal
Energy Storage
Published
2024-08-01
DOI
https://doi.org/10.1002/est2.70014
Citations
1
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High‐Performance Single‐Phase Bi‐Directional Novel On‐Board Charger for Electric Vehicles

Rajib Mandal, Amitesh Kumar, Md Inayat Ali
1 citations
Energy Storage
Advanced DC-DC Converters
0.21
article

High‐Performance Single‐Phase Bi‐Directional Novel On‐Board Charger for Electric Vehicles

Rajib Mandal, Amitesh Kumar, Md Inayat Ali
article en
1 citations

Abstract

ABSTRACT The design and development of a 550 W non‐isolated single‐phase two‐stage level‐1 bidirectional on‐board battery charger (OBC) for electric vehicles (EVs) have been discussed in this article, which is also capable of supplying the utility grid's reactive power needs. There are two stages in this topology. The first stage consists of a full bridge bidirectional AC to DC converter, and the second stage consists of a half‐bridge bidirectional DC to DC converter with enhanced vehicle‐to‐vehicle (V2V) capabilities for emergency roadside charging assistance scenarios. In an emergency, if there is not a charging station nearby and the battery is dead, EVs can use this feature to charge from other EVs. It can also work like a regular vehicle‐to‐grid (V2G) or grid‐to‐vehicle (G2V) system. The suggested charging topology has a maximum efficiency of 99.09%, a power factor of 0.99, and a total harmonic distortion (THD) of 6.31%. MATLAB/Simulink is used to develop and simulate the suggested EV charger, and simulation results are compared with the other on‐board chargers in the literature.

Energy StorageVol. 6(5)
National Institute of Technology Patna (IN)
Openalex Percentile: Top 49%
Advanced DC-DC Converters
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.