Carbon‐Nanotube Microelectrodes for Electrochemical Determination of Melatonin

Voltammetric methods hold promise for the rapid and sensitive quantification of melatonin. This study reports the direct electrochemical quantification of melatonin using carbon nanotube (CNT) fiber cross-sections as microelectrodes. Six identical highly densified CNT fiber cross-sections were employed to quantify melatonin in the range of 0.05-100 μM. The limit of detection and quantification were 10 and 35 nM, respectively, with a sensitivity of 0.1322 nA/μM. Interference studies with uric acid, hypoxanthine, and ascorbic acid demonstrate its performance. Real-world application was highlighted by measuring melatonin in food, pharmaceutical, and human urine samples.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2024-08-21
DOI
https://doi.org/10.1002/elan.202400191
Citations
6
Primary Topic
Photoreceptor and optogenetics research
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carbon‐Nanotube Microelectrodes for Electrochemical Determination of Melatonin

Neeraj Kumar, Noe T. Alvarez, Nilni E. Weerawarna
6 citations
Electroanalysis
Photoreceptor and optogenetics research
1.61
article

Carbon‐Nanotube Microelectrodes for Electrochemical Determination of Melatonin

Neeraj Kumar, Noe T. Alvarez, Nilni E. Weerawarna
article en
6 citations

Abstract

Voltammetric methods hold promise for the rapid and sensitive quantification of melatonin. This study reports the direct electrochemical quantification of melatonin using carbon nanotube (CNT) fiber cross-sections as microelectrodes. Six identical highly densified CNT fiber cross-sections were employed to quantify melatonin in the range of 0.05-100 μM. The limit of detection and quantification were 10 and 35 nM, respectively, with a sensitivity of 0.1322 nA/μM. Interference studies with uric acid, hypoxanthine, and ascorbic acid demonstrate its performance. Real-world application was highlighted by measuring melatonin in food, pharmaceutical, and human urine samples.

ElectroanalysisVol. 36(12)
University of Cincinnati (US)
National Science Foundation, National Institutes of Health
Responsible consumption and production
Openalex Percentile: Top 17%
Photoreceptor and optogenetics research
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.