Sigma performance evaluations for clinical chemistry and immunoassays in a tertiary care hospital laboratory based on Clinical Laboratory Improvement Amendments (CLIA) 1988 and 2024 Guidelines

Sigma metrics, implemented by clinical laboratories, utilize the performance of assays to evaluate both precision and accuracy by considering the recommended total allowable error (TEa). The study aims to evaluate the performance of 48 analytes (chemistry and immunological) performed in a tertiary care hospital laboratory and compare them with the TEa recommended by CLIA 1988 and 2024 guidelines. This study, conducted at the Biochemistry Department of Medanta Hospital, Lucknow, Uttar Pradesh, India, utilizes retrospective data of the period January 2023 to December 2023 to analyze the performance of 48 assays in terms of precision (percentage of coefficient of variation (CV%) from the internal quality control (IQC) data) and accuracy (Bias %) from the monthly data of external quality assessment services (EQAS). 28 clinical chemistry and 20 immunoassays were performed on an automated VITROS XT 7600 Integrated chemistry analyzer. Sigma scores were calculated and analyzed using a standard formula, which includes Bias%, CV%, and TEa for each assay. Based on TEa source from CLIA 1988 and 2024, for clinical chemistry assays - 64%, 46% showed sigma performance score of >6.0; 27%, 43% showed sigma performance score between 3.0 to 5.9; and 9%, 11% of showed sigma performance score of below 3.0 respectively. For immunoassays, based on TEa source from CLIA 2024, 55% showed a sigma performance score of >6.0, 35% showed a sigma performance score between 3.0 to 5.9, and 10% showed a sigma performance score of below 3.0. This study showed that about 90% of clinical chemistry and immunoassays produced excellent results on the sigma scale. The analysis helped to identify the root causes of the low performance of a few assays with a sigma score below 3.0 and the performance improvement steps undertaken.

Authors

Institutions

Publication Details

Journal
International Journal of Clinical Biochemistry and Research
Published
2024-08-15
DOI
https://doi.org/10.18231/j.ijcbr.2024.020
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sigma performance evaluations for clinical chemistry and immunoassays in a tertiary care hospital laboratory based on Clinical Laboratory Improvement Amendments (CLIA) 1988 and 2024 Guidelines

Kriti Singh, Bhavana Bais, Varijendra Tripathi
International Journal of Clinical Biochemistry and Research
Clinical Laboratory Practices and Quality Control
article

Sigma performance evaluations for clinical chemistry and immunoassays in a tertiary care hospital laboratory based on Clinical Laboratory Improvement Amendments (CLIA) 1988 and 2024 Guidelines

Kriti Singh, Bhavana Bais, Varijendra Tripathi
article en

Abstract

Sigma metrics, implemented by clinical laboratories, utilize the performance of assays to evaluate both precision and accuracy by considering the recommended total allowable error (TEa). The study aims to evaluate the performance of 48 analytes (chemistry and immunological) performed in a tertiary care hospital laboratory and compare them with the TEa recommended by CLIA 1988 and 2024 guidelines. This study, conducted at the Biochemistry Department of Medanta Hospital, Lucknow, Uttar Pradesh, India, utilizes retrospective data of the period January 2023 to December 2023 to analyze the performance of 48 assays in terms of precision (percentage of coefficient of variation (CV%) from the internal quality control (IQC) data) and accuracy (Bias %) from the monthly data of external quality assessment services (EQAS). 28 clinical chemistry and 20 immunoassays were performed on an automated VITROS XT 7600 Integrated chemistry analyzer. Sigma scores were calculated and analyzed using a standard formula, which includes Bias%, CV%, and TEa for each assay. Based on TEa source from CLIA 1988 and 2024, for clinical chemistry assays - 64%, 46% showed sigma performance score of >6.0; 27%, 43% showed sigma performance score between 3.0 to 5.9; and 9%, 11% of showed sigma performance score of below 3.0 respectively. For immunoassays, based on TEa source from CLIA 2024, 55% showed a sigma performance score of >6.0, 35% showed a sigma performance score between 3.0 to 5.9, and 10% showed a sigma performance score of below 3.0. This study showed that about 90% of clinical chemistry and immunoassays produced excellent results on the sigma scale. The analysis helped to identify the root causes of the low performance of a few assays with a sigma score below 3.0 and the performance improvement steps undertaken.

International Journal of Clinical Biochemistry and ResearchVol. 11(2)
Medanta The Medicity (IN)
Openalex Percentile: Top 81%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.