Mutually Orthogonal Complementary Golay Coded Sequences: An In-vivo Study

Fast and high-quality ultrasound imaging allows to increase the effectiveness of detecting tissue changes at the initial stage of disease. The aim of the study was to assess the quality of ultrasound imaging using mutually orthogonal, complementary Golay coded sequences (MOCGCS). Two 16-bits MOCGCS sets were implemented in the Verasonics Vantage™ scanner. Echoes from a perfect reflector, a custom-made nylon wire phantom, a tissue-mimicking phantom, and in-vivo scans of abdominal aorta and common carotid artery were recorded. Three parameters of the detected MOCGCS echoes: signal-to-noise ratio (SNR), side-lobe level (SLL), and axial resolution were evaluated and compared to the same parameters of the echoes recorded using standard complementary Golay sequences (CGS) and a short, one sine cycle pulse. The results revealed that MOCGCS transmission maintained comparable echo quality metrics (SNR, SLL, and axial resolution) compared to CGS and short pulses. Notably, both MOCGCS and CGS offered similar SNR improvements (5 dB–9 dB) in comparison to the short pulse for wires placed at depths up to 8 cm. Analysis of axial resolution, estimated at the full width at half maximum level, revealed near-identical values for all transmitted signals (0.17 µs for MOCGCS, 0.16 µs for CGS, and 0.18 µs for short pulse). MOCGCS implementation in ultrasound imaging offers the potential to significantly reduce image reconstruction time while maintaining image quality comparable to CGS sequences. In the experimental study we have shown that MOCGCS offers advantages over conventional CGS by enabling two times faster data acquisition and image reconstruction without compromising image quality.

Authors

Institutions

Publication Details

Journal
Archives of Acoustics
Published
2024-08-21
DOI
https://doi.org/10.24425/aoa.2024.148807
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mutually Orthogonal Complementary Golay Coded Sequences: An In-vivo Study

Andrzej Nowicki, Jurij Tasinkiewicz, Ihor Trots
Archives of Acoustics
Ultrasound Imaging and Elastography
article

Mutually Orthogonal Complementary Golay Coded Sequences: An In-vivo Study

Andrzej Nowicki, Jurij Tasinkiewicz, Ihor Trots
article en

Abstract

Fast and high-quality ultrasound imaging allows to increase the effectiveness of detecting tissue changes at the initial stage of disease. The aim of the study was to assess the quality of ultrasound imaging using mutually orthogonal, complementary Golay coded sequences (MOCGCS). Two 16-bits MOCGCS sets were implemented in the Verasonics Vantage™ scanner. Echoes from a perfect reflector, a custom-made nylon wire phantom, a tissue-mimicking phantom, and in-vivo scans of abdominal aorta and common carotid artery were recorded. Three parameters of the detected MOCGCS echoes: signal-to-noise ratio (SNR), side-lobe level (SLL), and axial resolution were evaluated and compared to the same parameters of the echoes recorded using standard complementary Golay sequences (CGS) and a short, one sine cycle pulse. The results revealed that MOCGCS transmission maintained comparable echo quality metrics (SNR, SLL, and axial resolution) compared to CGS and short pulses. Notably, both MOCGCS and CGS offered similar SNR improvements (5 dB–9 dB) in comparison to the short pulse for wires placed at depths up to 8 cm. Analysis of axial resolution, estimated at the full width at half maximum level, revealed near-identical values for all transmitted signals (0.17 µs for MOCGCS, 0.16 µs for CGS, and 0.18 µs for short pulse). MOCGCS implementation in ultrasound imaging offers the potential to significantly reduce image reconstruction time while maintaining image quality comparable to CGS sequences. In the experimental study we have shown that MOCGCS offers advantages over conventional CGS by enabling two times faster data acquisition and image reconstruction without compromising image quality.

Archives of Acoustics
Institute of Fundamental Technological Research (PL), Polish Academy of Sciences (PL)
Openalex Percentile: Top 77%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.