Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads—A Single-Center Experience

<i>Background and Objectives</i>: The number of cardiac pacemakers being used has increased in recent decades, and this increase has led to a rise in device-related complications, requiring percutaneous device extraction. Our aim was to present our single-center clinical experience in percutaneous lead extractions. <i>Materials and Methods</i>: We analyzed an observational retrospective cohort study of 93 patients for the transvenous removal of a total of 163 endocardial leads. We evaluated the device details, indications, lead characteristics, extraction methods, complications, reimplantation procedure, follow-up data, effectiveness, and safety. <i>Results</i>: Patients' mean age was 68.6 ± 11.6 years. Lead extraction indications were pocket infection in 33 (35.5%), lead dysfunction in 33 (35.5%), and system upgrade in 21 (23%) cases, and lead endocarditis in 6 (6%) cases. The duration from implantation to extraction time was a detected median of 43 (24-87) months. The most common retracted lead type was the RV defibrillator lead (62%), and the lead fixation type was active for one hundred (61%) patients. A new device was inserted in 74 (80%) patients, and the device type was most commonly a CRT-D (61%). Patients were followed up at a median of 17 (8-36) months, and 18 patients (19%) died at follow-up. Complete procedural success was obtained in 78 (84%) patients, and clinical procedural success was obtained in 83 (89%) patients. Procedural failure was detected in 15 (16%) patients. Major and minor complications were detected in 10 (11%) and 6 (6.5%) patients, respectively. The most common minor complication was pocket hematoma. <i>Conclusions</i>: Our experience suggests that transvenous lead extraction has a high success rate with an acceptable risk of procedural complications. The simple manual traction method has a high rate of procedural success, despite a high dwell time of the lead.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2024-08-21
DOI
https://doi.org/10.3390/medicina60081360
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads—A Single-Center Experience

Serkan Yüksel, Murat Akçay
Medicina
Cardiac pacing and defibrillation studies
article

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads—A Single-Center Experience

Serkan Yüksel, Murat Akçay
article en

Abstract

<i>Background and Objectives</i>: The number of cardiac pacemakers being used has increased in recent decades, and this increase has led to a rise in device-related complications, requiring percutaneous device extraction. Our aim was to present our single-center clinical experience in percutaneous lead extractions. <i>Materials and Methods</i>: We analyzed an observational retrospective cohort study of 93 patients for the transvenous removal of a total of 163 endocardial leads. We evaluated the device details, indications, lead characteristics, extraction methods, complications, reimplantation procedure, follow-up data, effectiveness, and safety. <i>Results</i>: Patients' mean age was 68.6 ± 11.6 years. Lead extraction indications were pocket infection in 33 (35.5%), lead dysfunction in 33 (35.5%), and system upgrade in 21 (23%) cases, and lead endocarditis in 6 (6%) cases. The duration from implantation to extraction time was a detected median of 43 (24-87) months. The most common retracted lead type was the RV defibrillator lead (62%), and the lead fixation type was active for one hundred (61%) patients. A new device was inserted in 74 (80%) patients, and the device type was most commonly a CRT-D (61%). Patients were followed up at a median of 17 (8-36) months, and 18 patients (19%) died at follow-up. Complete procedural success was obtained in 78 (84%) patients, and clinical procedural success was obtained in 83 (89%) patients. Procedural failure was detected in 15 (16%) patients. Major and minor complications were detected in 10 (11%) and 6 (6.5%) patients, respectively. The most common minor complication was pocket hematoma. <i>Conclusions</i>: Our experience suggests that transvenous lead extraction has a high success rate with an acceptable risk of procedural complications. The simple manual traction method has a high rate of procedural success, despite a high dwell time of the lead.

MedicinaVol. 60(8)
Ondokuz Mayıs University (TR)
Ondokuz Mayis Üniversitesi
Good health and well-being
Openalex Percentile: Top 75%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.