Effect of Chloride Salt Erosion on the Properties of Straw Fiber Reactive Powder Concrete

Straw fibers are renowned for their cost-effectiveness, sustainability, and durability. They represent a promising natural reinforcement option for reactive powder concrete (RPC). This paper investigated the impact of straw fibers on RPC’s workability, mechanical performance (mechanical strength and flexural toughness), and electrical properties (electrical resistance and AC impedance spectroscopy curves). The straw fiber volumes ranged from 1% to 4.0% of the total RPC volume. Specimens were cured under standard curing conditions for 3, 7, 14, and 28 days. Mechanical and electrical properties of the specimens were tested before chloride salt erosion. The mass loss and ultrasonic velocity loss of the samples were measured under NaCl freeze–thaw cycles (F-Cs). The mass loss, ultrasonic velocity loss, and mechanical strengths loss of the samples were measured under NaCl dry–wet alternations (D-As). The findings indicated that incorporating straw fibers enhanced RPC’s flexural strength, compressive strength, and flexural toughness by 21.3% to 45.76%, −7.16% to 11.62%, and 2.4% to 32.7%, respectively, following a 28-day curing period. The addition of straw fibers could augment the AC electrical resistance of the RPC by 10.17% to 58.1%. The electrical characteristics of the RPC adhered to series conduction models. A power function relationship existed between the electrical resistance and mechanical strengths of the RPC. After 10 NaCl D-As, the mass loss rate, ultrasonic velocity loss rate, flexural strength, and compressive strength loss rates of the RPC decreased by 0.42% to 1.68%, 2.69% to 6.73%, 9.6% to 35.65%, and 5.41% to 34.88%, respectively, compared to blank samples. After undergoing 200 NaCl F-Cs, the rates of mass loss and ultrasonic velocity loss of the RPC decreased by 0.89% to 1.01% and 6.68% to 8.9%, respectively.

Authors

Institutions

Publication Details

Journal
Coatings
Published
2024-08-21
DOI
https://doi.org/10.3390/coatings14081069
Citations
8
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
2.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Chloride Salt Erosion on the Properties of Straw Fiber Reactive Powder Concrete

Bingang Xu, Xi Peng, Hui Wang, Kaiwei Gong et al.
8 citations
Coatings
Innovative concrete reinforcement materials
2.09
article

Effect of Chloride Salt Erosion on the Properties of Straw Fiber Reactive Powder Concrete

Bingang Xu, Xi Peng, Hui Wang, Kaiwei Gong, H. Wang, Bingling Cheng
article en
8 citations

Abstract

Straw fibers are renowned for their cost-effectiveness, sustainability, and durability. They represent a promising natural reinforcement option for reactive powder concrete (RPC). This paper investigated the impact of straw fibers on RPC’s workability, mechanical performance (mechanical strength and flexural toughness), and electrical properties (electrical resistance and AC impedance spectroscopy curves). The straw fiber volumes ranged from 1% to 4.0% of the total RPC volume. Specimens were cured under standard curing conditions for 3, 7, 14, and 28 days. Mechanical and electrical properties of the specimens were tested before chloride salt erosion. The mass loss and ultrasonic velocity loss of the samples were measured under NaCl freeze–thaw cycles (F-Cs). The mass loss, ultrasonic velocity loss, and mechanical strengths loss of the samples were measured under NaCl dry–wet alternations (D-As). The findings indicated that incorporating straw fibers enhanced RPC’s flexural strength, compressive strength, and flexural toughness by 21.3% to 45.76%, −7.16% to 11.62%, and 2.4% to 32.7%, respectively, following a 28-day curing period. The addition of straw fibers could augment the AC electrical resistance of the RPC by 10.17% to 58.1%. The electrical characteristics of the RPC adhered to series conduction models. A power function relationship existed between the electrical resistance and mechanical strengths of the RPC. After 10 NaCl D-As, the mass loss rate, ultrasonic velocity loss rate, flexural strength, and compressive strength loss rates of the RPC decreased by 0.42% to 1.68%, 2.69% to 6.73%, 9.6% to 35.65%, and 5.41% to 34.88%, respectively, compared to blank samples. After undergoing 200 NaCl F-Cs, the rates of mass loss and ultrasonic velocity loss of the RPC decreased by 0.89% to 1.01% and 6.68% to 8.9%, respectively.

CoatingsVol. 14(8)
Ningbo University (CN), Ningbo University of Technology (CN)
Responsible consumption and production
Openalex Percentile: Top 14%
Innovative concrete reinforcement materials
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.