Mycological contamination of cabin filters as a potential source of air pollution inside passenger vehicles

Abstract Microbiological pollutants of cabin filters may affect the air quality inside vehicles. The main aim of the study was to evaluate cabin filters in terms of their effectiveness in retaining mycological contaminants. The research material consisted of 100 cabin filters obtained during periodic replacement of filters in passenger cars. Mycological contamination of filters was examined using microbiological, biochemical, immunoenzymatic and molecular methods. The average concentration of fungi in cabin filters was 7.2 × 10 7 CFU/m 2 , and Cladosporium , Alternaria , Penicillium , and Aspergillu s genera were most often isolated. For Aspergillus species, the highest concentration reached 3.3 × 10 7 CFU/m 2 , with dominance of A. fumigatus . Among the Aspergillus strains tested, the presence of the aflO gene related to aflatoxin biosynthesis and the polyketide synthase gene related to ochratoxin A biosynthesis was detected. The presence of total aflatoxin (B 1 , B 2 , G 1 , G 2 ) and aflatoxin B 1 was detected at levels of 5.37 µg/kg and 1.71 µg/kg for standard filters and 2.43 µg/kg and 0.65 µg/kg for carbon filters. The level of ochratoxin A contamination was 0.96 µg/kg and 0.55 µg/kg for standard and carbon filters, respectively. Aspergillus species showed high enzymatic activity of acid phosphatase, β-glucosidase, naphthol phosphohydrolase and N-acetyl-β-glucosamidase. Based on the test results regarding the concentration of mycotoxins and the effectiveness of capturing fungal conidia, it was found that carbon filters are more effective than standard filters. Recommendations for filter manufacturers and car service policies should include the use of cabin filters with a layer of activated carbon, and their regular replacement after a year of use.

Authors

Institutions

Publication Details

Journal
Air Quality Atmosphere & Health
Published
2024-08-21
DOI
https://doi.org/10.1007/s11869-024-01631-1
Citations
5
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
1.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mycological contamination of cabin filters as a potential source of air pollution inside passenger vehicles

Ewelina Farian, Angelina Wójcik‐Fatla
5 citations
Air Quality Atmosphere & Health
Indoor Air Quality and Microbial Exposure
1.57
article

Mycological contamination of cabin filters as a potential source of air pollution inside passenger vehicles

Ewelina Farian, Angelina Wójcik‐Fatla
article en
5 citations

Abstract

Abstract Microbiological pollutants of cabin filters may affect the air quality inside vehicles. The main aim of the study was to evaluate cabin filters in terms of their effectiveness in retaining mycological contaminants. The research material consisted of 100 cabin filters obtained during periodic replacement of filters in passenger cars. Mycological contamination of filters was examined using microbiological, biochemical, immunoenzymatic and molecular methods. The average concentration of fungi in cabin filters was 7.2 × 10 7 CFU/m 2 , and Cladosporium , Alternaria , Penicillium , and Aspergillu s genera were most often isolated. For Aspergillus species, the highest concentration reached 3.3 × 10 7 CFU/m 2 , with dominance of A. fumigatus . Among the Aspergillus strains tested, the presence of the aflO gene related to aflatoxin biosynthesis and the polyketide synthase gene related to ochratoxin A biosynthesis was detected. The presence of total aflatoxin (B 1 , B 2 , G 1 , G 2 ) and aflatoxin B 1 was detected at levels of 5.37 µg/kg and 1.71 µg/kg for standard filters and 2.43 µg/kg and 0.65 µg/kg for carbon filters. The level of ochratoxin A contamination was 0.96 µg/kg and 0.55 µg/kg for standard and carbon filters, respectively. Aspergillus species showed high enzymatic activity of acid phosphatase, β-glucosidase, naphthol phosphohydrolase and N-acetyl-β-glucosamidase. Based on the test results regarding the concentration of mycotoxins and the effectiveness of capturing fungal conidia, it was found that carbon filters are more effective than standard filters. Recommendations for filter manufacturers and car service policies should include the use of cabin filters with a layer of activated carbon, and their regular replacement after a year of use.

Air Quality Atmosphere & HealthVol. 18(1)
Instytut Medycyny Wsi im. Witolda Chodźki (PL)
Vlaamse regering, Narodowe Centrum Badań i Rozwoju
Openalex Percentile: Top 18%
Indoor Air Quality and Microbial Exposure
1.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.