Recent improvements in the novel approach to the fast detection of surface contaminations

Abstract Here, we present the idea behind a novel measurement system and the recent improvements in detecting surface contaminations using a tunable, very fast three-core quantum cascade laser (QCL) system. It is developed as a potential replacement for the old established double-wheel sampling system currently used to detect surface threats caused by hazardous, non-volatile chemical substances. The novel system design is based on an optical measurement principle, allowing standoff detection and identification, thus rendering ground contact unnecessary. One of the leading military requirements for a CBRN reconnaissance vehicle is a high marching speed; hence, this new system is designed to have an ultra-short acquisition time and an adequate spectral bandwidth for measurements in the mid-infrared (MIR). This innovative approach may replace the more cumbersome indirect detection techniques. We discuss the main advantages and evaluate possible application scenarios that we expect from this setup. Active IR backscatter spectroscopy generally permits the contactless identification of hazardous chemical substances on surfaces. Here, the design was optimized around an approximate measuring distance of decimeters. Using a monoaxial setup, the autofocus is less demanding than alternative approaches and even allows for rapid measurements of rough surfaces. We built the improved measurement system based on novel QCL modules that integrate micro-opto-electro-mechanical grating scanners (MOEMS) in an external cavity. These elaborate laser modules provide almost one kilohertz (kHz) spectral scan speeds and typically cover a spectral range of 200–300 cm -1 , respectively. Furthermore, such modules achieve measurement times of as short as one millisecond per spectrum. The full spectral coverage of the system is realized by coupling several of such modules.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2024-08-21
DOI
https://doi.org/10.1140/epjp/s13360-024-05499-z
Citations
2
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recent improvements in the novel approach to the fast detection of surface contaminations

Yuri V. Flores, Arne Ficks, Frank Wilsenack, Marko Haertelt et al.
2 citations
The European Physical Journal Plus
Spectroscopy and Laser Applications
0.48
article

Recent improvements in the novel approach to the fast detection of surface contaminations

Yuri V. Flores, Arne Ficks, Frank Wilsenack, Marko Haertelt, Fabian Meyer, Mario Adelhardt
article en
2 citations

Abstract

Abstract Here, we present the idea behind a novel measurement system and the recent improvements in detecting surface contaminations using a tunable, very fast three-core quantum cascade laser (QCL) system. It is developed as a potential replacement for the old established double-wheel sampling system currently used to detect surface threats caused by hazardous, non-volatile chemical substances. The novel system design is based on an optical measurement principle, allowing standoff detection and identification, thus rendering ground contact unnecessary. One of the leading military requirements for a CBRN reconnaissance vehicle is a high marching speed; hence, this new system is designed to have an ultra-short acquisition time and an adequate spectral bandwidth for measurements in the mid-infrared (MIR). This innovative approach may replace the more cumbersome indirect detection techniques. We discuss the main advantages and evaluate possible application scenarios that we expect from this setup. Active IR backscatter spectroscopy generally permits the contactless identification of hazardous chemical substances on surfaces. Here, the design was optimized around an approximate measuring distance of decimeters. Using a monoaxial setup, the autofocus is less demanding than alternative approaches and even allows for rapid measurements of rough surfaces. We built the improved measurement system based on novel QCL modules that integrate micro-opto-electro-mechanical grating scanners (MOEMS) in an external cavity. These elaborate laser modules provide almost one kilohertz (kHz) spectral scan speeds and typically cover a spectral range of 200–300 cm -1 , respectively. Furthermore, such modules achieve measurement times of as short as one millisecond per spectrum. The full spectral coverage of the system is realized by coupling several of such modules.

The European Physical Journal PlusVol. 139(8)
Fraunhofer Institute for Applied Solid State Physics (DE)
Openalex Percentile: Top 41%
Spectroscopy and Laser Applications
0.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.