Failure analysis of 12Cr1MoVG outlet header for the reheater of the boiler under high temperature and high-pressure environment

After operating for 11,640 h, a boiler failed due to multiple cracks generated in the inner wall of the outlet header for the reheater. A thorough analysis was conducted in this work, including evidence and specimen collection, chemical composition analysis, tensile and impact test analysis, metallographic analysis, energy dispersive spectroscopy (EDS) analysis, and electron backscattering diffraction (EBSD) characterisation, to reveal the causes of cracks in the outlet header of the reheater. The tensile strength-Rm and the average micro-Vickers hardness of the outlet header is 496 MPa and 168 HV, respectively. Besides, the microstructure was found to meet the requirements of the relevant standards. The grains near the crack exhibited different degrees of deformation, and the deformation degree increased with the decreasing distance from the crack. In addition, the grains with the Schmid factor value greater than 0.3 accounted for 99.8% near the crack, indicating that the grains surrounding the crack were predominantly soft orientation grains. Thus, many deformation bands mainly composed of low-angle boundaries were induced inside the grains near the crack. Eventually, it was concluded that alkali stress corrosion and thermal fatigue resulted in the failure of the outlet header.

Authors

Institutions

Publication Details

Journal
Canadian Metallurgical Quarterly
Published
2024-08-22
DOI
https://doi.org/10.1080/00084433.2024.2393540
Citations
2
Primary Topic
High Temperature Alloys and Creep
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure analysis of 12Cr1MoVG outlet header for the reheater of the boiler under high temperature and high-pressure environment

Chenkai Ying, Fengping Zhong, Ting Yu, Zhen Gao et al.
2 citations
Canadian Metallurgical Quarterly
High Temperature Alloys and Creep
0.43
article

Failure analysis of 12Cr1MoVG outlet header for the reheater of the boiler under high temperature and high-pressure environment

Chenkai Ying, Fengping Zhong, Ting Yu, Zhen Gao, Zimeng Wang
article en
2 citations

Abstract

After operating for 11,640 h, a boiler failed due to multiple cracks generated in the inner wall of the outlet header for the reheater. A thorough analysis was conducted in this work, including evidence and specimen collection, chemical composition analysis, tensile and impact test analysis, metallographic analysis, energy dispersive spectroscopy (EDS) analysis, and electron backscattering diffraction (EBSD) characterisation, to reveal the causes of cracks in the outlet header of the reheater. The tensile strength-Rm and the average micro-Vickers hardness of the outlet header is 496 MPa and 168 HV, respectively. Besides, the microstructure was found to meet the requirements of the relevant standards. The grains near the crack exhibited different degrees of deformation, and the deformation degree increased with the decreasing distance from the crack. In addition, the grains with the Schmid factor value greater than 0.3 accounted for 99.8% near the crack, indicating that the grains surrounding the crack were predominantly soft orientation grains. Thus, many deformation bands mainly composed of low-angle boundaries were induced inside the grains near the crack. Eventually, it was concluded that alkali stress corrosion and thermal fatigue resulted in the failure of the outlet header.

Canadian Metallurgical QuarterlyVol. 64(3)
Zhejiang Institute of Special Equipment Inspection (CN)
Affordable and clean energy
Openalex Percentile: Top 43%
High Temperature Alloys and Creep
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.