Silicon photomultipliers for future HEP experiments

For the particle identification systems of the future high-energy physics detectors, single-photon sensors with sub-mm granularity, high sensitivity, and mitigation strategy for operation in the neutron-irradiated areas are needed. Silicon photomultipliers are considered a baseline technology because of their high photon detection efficiency, good timing resolution, and low operating voltage compared to those of vacuum-based photo sensors. After neutron irradiation, the dark counts increase dramatically and distort the signal baseline, making the single photons indistinguishable. Although the DCR of different unirradiated SiPMs varies, the devices show very similar rates when irradiated to high doses. In this work, we investigated the performance parameters of FBK NUV-HD-RH UHD-DE 1 mm 2 devices and determined the working temperature. We show that the maximum operation temperature for samples irradiated with a fluence of 1 0 12 neq/cm 2 is around -100 ° C .

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2024-08-22
DOI
https://doi.org/10.1016/j.nima.2024.169776
Citations
1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Silicon photomultipliers for future HEP experiments

A. Seljak, S. Korpar, R. Dolenec, R. Pestotnik et al.
1 citations
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
0.66
article

Silicon photomultipliers for future HEP experiments

A. Seljak, S. Korpar, R. Dolenec, R. Pestotnik, D. Consuegra, P. Križan
article en
1 citations

Abstract

For the particle identification systems of the future high-energy physics detectors, single-photon sensors with sub-mm granularity, high sensitivity, and mitigation strategy for operation in the neutron-irradiated areas are needed. Silicon photomultipliers are considered a baseline technology because of their high photon detection efficiency, good timing resolution, and low operating voltage compared to those of vacuum-based photo sensors. After neutron irradiation, the dark counts increase dramatically and distort the signal baseline, making the single photons indistinguishable. Although the DCR of different unirradiated SiPMs varies, the devices show very similar rates when irradiated to high doses. In this work, we investigated the performance parameters of FBK NUV-HD-RH UHD-DE 1 mm 2 devices and determined the working temperature. We show that the maximum operation temperature for samples irradiated with a fluence of 1 0 12 neq/cm 2 is around -100 ° C .

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1068
University of Ljubljana (SI), Jožef Stefan Institute (SI), University of Maribor (SI)
Institut "Jožef Stefan", European Commission, Fondazione Bruno Kessler, Javna Agencija za Raziskovalno Dejavnost RS
Openalex Percentile: Top 15%
Particle Detector Development and Performance
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.