Fault-Tolerant Control of Active Power Filter With Balanced Three-Phase Line Currents

Transformer isolated three-phase three-wire two-level active power filters (APF) using pulse width modulated (PWM) control are widely used for shunt compensation of harmonic currents. In a situation when only two of the converter legs remain connected to the grid due to an open circuit fault in one of the converter legs or its internal lines or in one of its line reactors, the existing fault-tolerant schemes cannot continue operation with balanced grid side line currents, resulting in improper harmonic compensation. A new control scheme is proposed in this article by which APF can seamlessly continue fault-tolerant operation during single line open-circuit fault and inject balanced three-phase harmonic currents into the line for proper compensation, without requiring any redundant legs or switches to change the internal power configuration. Unlike conventional APF schemes, a simple control scheme is proposed to adjust the phase shift between the composite harmonic currents in the two operative legs of the converter connected to the grid via a full rated delta/star isolation transformer (or an existing delta-star distribution transformer) with neutral connected to dc bus midpoint to inject balanced harmonic currents into the grid. Simulation and experimental results are provided to validate the effectiveness of proposed concept.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2024-08-22
DOI
https://doi.org/10.1109/tie.2024.3440514
Citations
2
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault-Tolerant Control of Active Power Filter With Balanced Three-Phase Line Currents

Sujit K. Biswas, Dipten Maiti, Abanishwar Chakrabarti, Soham Chakraborty
2 citations
IEEE Transactions on Industrial Electronics
Power Quality and Harmonics
0.42
article

Fault-Tolerant Control of Active Power Filter With Balanced Three-Phase Line Currents

Sujit K. Biswas, Dipten Maiti, Abanishwar Chakrabarti, Soham Chakraborty
article en
2 citations

Abstract

Transformer isolated three-phase three-wire two-level active power filters (APF) using pulse width modulated (PWM) control are widely used for shunt compensation of harmonic currents. In a situation when only two of the converter legs remain connected to the grid due to an open circuit fault in one of the converter legs or its internal lines or in one of its line reactors, the existing fault-tolerant schemes cannot continue operation with balanced grid side line currents, resulting in improper harmonic compensation. A new control scheme is proposed in this article by which APF can seamlessly continue fault-tolerant operation during single line open-circuit fault and inject balanced three-phase harmonic currents into the line for proper compensation, without requiring any redundant legs or switches to change the internal power configuration. Unlike conventional APF schemes, a simple control scheme is proposed to adjust the phase shift between the composite harmonic currents in the two operative legs of the converter connected to the grid via a full rated delta/star isolation transformer (or an existing delta-star distribution transformer) with neutral connected to dc bus midpoint to inject balanced harmonic currents into the grid. Simulation and experimental results are provided to validate the effectiveness of proposed concept.

IEEE Transactions on Industrial ElectronicsVol. 72(3)
Jadavpur University (IN), National Institute of Technology Agartala (IN)
Affordable and clean energy
Openalex Percentile: Top 39%
Power Quality and Harmonics
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.