mm-MuRe: mmWave-Based Multi-Subject Respiration Monitoring via End-to-End Deep Learning

This study presents <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mm-MuRe</small>, a novel method to perform multi-subject contactless respiration waveform monitoring by processing raw multiple-input-multiple-output mmWave radar data with an end-to-end deep neural network. The traditional vital signs monitoring signal processing scheme for mmWave radar involves analog or digital beamforming, human subject localization, phase variation extraction, filtering, and rate or biomarker analysis. This traditional method has many downsides, including sensitivity to selected beamforming weights and over-reliance on phase variation. To avoid these drawbacks, <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mm-MuRe</small> (for MM-wave based MUlti-subject REspiration monitoring) is developed to improve reconstruction accuracy and reliability by taking in unprocessed 60 GHz MIMO FMCW radar data and outputting respiratory waveforms of interest, effectively mimicking an adaptive beamformer and bypassing the need for traditional localization and vital signs extraction techniques. Extensive testing across scenarios differing in range, angle, environment, and subject count demonstrates the network's robust performance, with an average cosine similarity exceeding 0.95. Results are compared to two baseline methods and show more than a 10% average improvement in waveform reconstruction accuracy across single and multi-subject scenarios. Coupled with a rapid inference time of 8.57 ms on a 10 s window of data, <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mm-MuRe</small> shows promise for potential deployment to efficient and accurate near-real-time contactless respiration monitoring systems.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Published
2024-08-22
DOI
https://doi.org/10.1109/jerm.2024.3443782
Citations
7
Primary Topic
Millimeter-Wave Propagation and Modeling
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

mm-MuRe: mmWave-Based Multi-Subject Respiration Monitoring via End-to-End Deep Learning

Abdel-Kareem Moadi, Chandler J. Bauder, Jian Liu, Aly E. Fathy et al.
7 citations
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Millimeter-Wave Propagation and Modeling
1.46
article

mm-MuRe: mmWave-Based Multi-Subject Respiration Monitoring via End-to-End Deep Learning

Abdel-Kareem Moadi, Chandler J. Bauder, Jian Liu, Aly E. Fathy, Vijaysrinivas Rajagopal, Tianhao Wu
article en
7 citations

Abstract

This study presents <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mm-MuRe</small>, a novel method to perform multi-subject contactless respiration waveform monitoring by processing raw multiple-input-multiple-output mmWave radar data with an end-to-end deep neural network. The traditional vital signs monitoring signal processing scheme for mmWave radar involves analog or digital beamforming, human subject localization, phase variation extraction, filtering, and rate or biomarker analysis. This traditional method has many downsides, including sensitivity to selected beamforming weights and over-reliance on phase variation. To avoid these drawbacks, <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mm-MuRe</small> (for MM-wave based MUlti-subject REspiration monitoring) is developed to improve reconstruction accuracy and reliability by taking in unprocessed 60 GHz MIMO FMCW radar data and outputting respiratory waveforms of interest, effectively mimicking an adaptive beamformer and bypassing the need for traditional localization and vital signs extraction techniques. Extensive testing across scenarios differing in range, angle, environment, and subject count demonstrates the network's robust performance, with an average cosine similarity exceeding 0.95. Results are compared to two baseline methods and show more than a 10% average improvement in waveform reconstruction accuracy across single and multi-subject scenarios. Coupled with a rapid inference time of 8.57 ms on a 10 s window of data, <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mm-MuRe</small> shows promise for potential deployment to efficient and accurate near-real-time contactless respiration monitoring systems.

IEEE Journal of Electromagnetics RF and Microwaves in Medicine and BiologyVol. 9(1)
Knoxville College (US), Film Independent (US)
National Science Foundation
Openalex Percentile: Top 18%
Millimeter-Wave Propagation and Modeling
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.