Glass capillary systems for micro-volume fluorometry
• Reduction in consumption of florescent materials required for analysis is discussed. • Systems using cuvettes, capillaries and anti-resonant hollow core fibers are compared. • Performance of capillary-based system is optimized for green fluorescent protein (GFP). • Volumes and GFP concentration as low as 2.9 μL and 1.5 nM were analysed, respectively. • The solution is versatile, cost-effective and makes minimization of wastes possible. Capillary-based fluorometry can be considered a promising alternative to cuvette-based methods, enabling low-volume measurements while reducing analyte consumption and waste generation. In this work, we compared the performance of three types of glass container systems, i.e., anti-resonant hollow core fibers, capillaries, and standard cuvettes, using green fluorescent protein (GFP) as a reference analyte. Among these, when the volume of the analyte and the fluorescence intensity are assessed, a capillary accommodating 2.9 μL was found as an optimal choice. The capillary-based interrogation setup was further optimized to enhance sensitivity by adjusting the florescence-exciting laser beam position and optimizing the capillary’s shape. The obtained capillary-based setup achieved a noteworthy 85 % reduction in sample volume compared to previous studies utilizing capillary-based fluorometry, highlighting its significant contribution to material conservation. The system achieved a limit of detection as low as 26 μg/mL (1.01 nM) GFP concentration and a resolution of 3.5 μg/mL. With its low cost and potential for reusability, capillary-based fluorometry presents a compelling alternative to traditional cuvette-based fluorometry, offering a promising solution for micro-volume analysis.
Authors
- Grzegorz Stępniewski (ORCID: https://orcid.org/0000-0003-2286-6764)
- Monika Janik (ORCID: https://orcid.org/0000-0002-8002-3055)
- Yuan Gong (ORCID: https://orcid.org/0000-0001-6819-8402)
- Ryszard Buczyński (ORCID: https://orcid.org/0000-0003-2863-725X)
- Rafał Kasztelanic (ORCID: https://orcid.org/0000-0002-6901-4641)
- Jakub Sikora
- Emil Pituła
- Marcin Olszewski (ORCID: https://orcid.org/0000-0002-5116-2793)
- Mateusz Śmietana (ORCID: https://orcid.org/0000-0002-6774-2426)
- Marcin Koba (ORCID: https://orcid.org/0000-0002-0295-8242)
Institutions
- Warsaw University of Technology (PL)
- University of Electronic Science and Technology of China (CN)
- National Institute of Telecommunications (PL)
- Łukasiewicz Research Network (PL)
- University of Warsaw (PL)
Publication Details
- Journal
- Measurement
- Published
- 2024-08-22
- DOI
- https://doi.org/10.1016/j.measurement.2024.115569
- Citations
- 3
- Primary Topic
- Surface Modification and Superhydrophobicity
- Type
- article
- Field-Weighted Citation Impact
- 0.54
Funders
- Narodowe Centrum Badań i Rozwoju