Glass capillary systems for micro-volume fluorometry

• Reduction in consumption of florescent materials required for analysis is discussed. • Systems using cuvettes, capillaries and anti-resonant hollow core fibers are compared. • Performance of capillary-based system is optimized for green fluorescent protein (GFP). • Volumes and GFP concentration as low as 2.9 μL and 1.5 nM were analysed, respectively. • The solution is versatile, cost-effective and makes minimization of wastes possible. Capillary-based fluorometry can be considered a promising alternative to cuvette-based methods, enabling low-volume measurements while reducing analyte consumption and waste generation. In this work, we compared the performance of three types of glass container systems, i.e., anti-resonant hollow core fibers, capillaries, and standard cuvettes, using green fluorescent protein (GFP) as a reference analyte. Among these, when the volume of the analyte and the fluorescence intensity are assessed, a capillary accommodating 2.9 μL was found as an optimal choice. The capillary-based interrogation setup was further optimized to enhance sensitivity by adjusting the florescence-exciting laser beam position and optimizing the capillary’s shape. The obtained capillary-based setup achieved a noteworthy 85 % reduction in sample volume compared to previous studies utilizing capillary-based fluorometry, highlighting its significant contribution to material conservation. The system achieved a limit of detection as low as 26 μg/mL (1.01 nM) GFP concentration and a resolution of 3.5 μg/mL. With its low cost and potential for reusability, capillary-based fluorometry presents a compelling alternative to traditional cuvette-based fluorometry, offering a promising solution for micro-volume analysis.

Authors

Institutions

Publication Details

Journal
Measurement
Published
2024-08-22
DOI
https://doi.org/10.1016/j.measurement.2024.115569
Citations
3
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glass capillary systems for micro-volume fluorometry

Grzegorz Stępniewski, Monika Janik, Yuan Gong, Ryszard Buczyński et al.
3 citations
Measurement
Surface Modification and Superhydrophobicity
0.54
article

Glass capillary systems for micro-volume fluorometry

Grzegorz Stępniewski, Monika Janik, Yuan Gong, Ryszard Buczyński, Rafał Kasztelanic, Jakub Sikora, Emil Pituła, Marcin Olszewski, Mateusz Śmietana, Marcin Koba
article en
3 citations

Abstract

• Reduction in consumption of florescent materials required for analysis is discussed. • Systems using cuvettes, capillaries and anti-resonant hollow core fibers are compared. • Performance of capillary-based system is optimized for green fluorescent protein (GFP). • Volumes and GFP concentration as low as 2.9 μL and 1.5 nM were analysed, respectively. • The solution is versatile, cost-effective and makes minimization of wastes possible. Capillary-based fluorometry can be considered a promising alternative to cuvette-based methods, enabling low-volume measurements while reducing analyte consumption and waste generation. In this work, we compared the performance of three types of glass container systems, i.e., anti-resonant hollow core fibers, capillaries, and standard cuvettes, using green fluorescent protein (GFP) as a reference analyte. Among these, when the volume of the analyte and the fluorescence intensity are assessed, a capillary accommodating 2.9 μL was found as an optimal choice. The capillary-based interrogation setup was further optimized to enhance sensitivity by adjusting the florescence-exciting laser beam position and optimizing the capillary’s shape. The obtained capillary-based setup achieved a noteworthy 85 % reduction in sample volume compared to previous studies utilizing capillary-based fluorometry, highlighting its significant contribution to material conservation. The system achieved a limit of detection as low as 26 μg/mL (1.01 nM) GFP concentration and a resolution of 3.5 μg/mL. With its low cost and potential for reusability, capillary-based fluorometry presents a compelling alternative to traditional cuvette-based fluorometry, offering a promising solution for micro-volume analysis.

MeasurementVol. 240
Warsaw University of Technology (PL), University of Electronic Science and Technology of China (CN), National Institute of Telecommunications (PL), Łukasiewicz Research Network (PL), University of Warsaw (PL)
Narodowe Centrum Badań i Rozwoju
Affordable and clean energy
Openalex Percentile: Top 39%
Surface Modification and Superhydrophobicity
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.