Performance testing of a novel short axis photomultiplier tube for the HUNT project

Abstract Photomultiplier tubes (PMTs) with large-area cathodes are increasingly being used in cosmic-ray experiments to enhance detection efficiency. The optical modules (OMs) of the High-Energy Underwater Neutrino Telescope (HUNT) have employed a brand new N6205 20-inch microchannel plate photomultiplier tube (MCP-PMT) developed by the North Night Vision Science & Technology (Nanjing) Research Institute Co. Ltd. (NNVT). In order to make the 20-inch PMT fit into the 23-inch diameter pressure-resistant glass sphere, NNVT improved the internal structure of PMT and shortened the height of PMT by more than 10 cm. The first batch of these PMTs has been delivered for preliminary research work. This paper describes a specific PMT testing platform built for the first batch of 15 MCP-PMTs, and some performance parameters of PMT, such as peak-to-valley ratio, TTS and nonliniearity, are measured. The measurement results show that the new PMT still has good performance and can meet the requirements of HUNT project.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-08-01
DOI
https://doi.org/10.1088/1748-0221/19/08/t08006
Citations
1
Primary Topic
Dark Matter and Cosmic Phenomena
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance testing of a novel short axis photomultiplier tube for the HUNT project

Zike Wang, Maoyuan Liu, X. H. You, Ling Ren et al.
1 citations
Journal of Instrumentation
Dark Matter and Cosmic Phenomena
0.66
article

Performance testing of a novel short axis photomultiplier tube for the HUNT project

Zike Wang, Maoyuan Liu, X. H. You, Ling Ren, Kai Li, Mingjun Chen, Bo Gao, Yijiang Peng, Y A Tang
article en
1 citations

Abstract

Abstract Photomultiplier tubes (PMTs) with large-area cathodes are increasingly being used in cosmic-ray experiments to enhance detection efficiency. The optical modules (OMs) of the High-Energy Underwater Neutrino Telescope (HUNT) have employed a brand new N6205 20-inch microchannel plate photomultiplier tube (MCP-PMT) developed by the North Night Vision Science & Technology (Nanjing) Research Institute Co. Ltd. (NNVT). In order to make the 20-inch PMT fit into the 23-inch diameter pressure-resistant glass sphere, NNVT improved the internal structure of PMT and shortened the height of PMT by more than 10 cm. The first batch of these PMTs has been delivered for preliminary research work. This paper describes a specific PMT testing platform built for the first batch of 15 MCP-PMTs, and some performance parameters of PMT, such as peak-to-valley ratio, TTS and nonliniearity, are measured. The measurement results show that the new PMT still has good performance and can meet the requirements of HUNT project.

Journal of InstrumentationVol. 19(08)
Tibet University (CN), Chengdu Organic Chemicals (China) (CN), Institute of High Energy Physics (CN), University of Chinese Academy of Sciences (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 15%
Dark Matter and Cosmic Phenomena
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance testing of a novel short axis photomultiplier tube for the HUNT project — Zike Wang, Maoyuan Liu, et al. · Journal of Instrumentation (2024) | TGRS Research Map | TGRS