A Cost‐Effective Electrochemical Sensor Using a Graphite Pencil Electrode for Sensitive Quantification of Phenolic Antioxidants in Human Plasma and Food Samples

Abstract The pressing challenge in electroanalysis revolves around the creation of a user‐friendly analytical sensor that is accessible to individuals lacking specialized expertise. Such sensor should offer minimal cost, while simultaneously ensuring high sensitivity and reproducibility. Herein, graphite pencil electrode (GPE) has emerged as a promising electrochemical sensor for the determination of polyphenolic compounds, including gentisic acid (GEN), gallic acid (GA), caffeic acid (CAF), and sinapic acid (SA). To comprehensively explore the electrochemical oxidation processes of these antioxidants, a range of electrochemical techniques, namely cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA), were deployed. The results of these investigations unveiled a diffusional oxidation wave associated with phenolic hydroxyl groups, involving a two‐electron/two‐proton loss step, occurring within the potential range of 0.4–0.6 V vs . Ag/AgCl. Crucially, the GPE exhibited the capacity to establish linear calibration curves for GEN, GA, CAF, and SA, encompassing concentrations from nanomolar to sub‐micromolar which highlighted by the corresponding limits of detection (LoD), recorded at 0.086, 0.046, 0.112, and 0.115 μM, respectively. The heightened sensitivity and reproducibility demonstrated by the GPE underscore its potential as an efficient tool for the determination of polyphenolic compounds. Beyond its analytical capabilities, the GPE displayed remarkable applicability in facilitating on‐site, cost‐effective determinations of polyphenolic compounds in both plasma and food samples. This versatility positions the GPE as a valuable asset in addressing the challenges associated with electrochemical analysis, making it an attractive option for a wide range of applications where simplicity, affordability, and reliability are paramount.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2024-08-22
DOI
https://doi.org/10.1002/elan.202400103
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Cost‐Effective Electrochemical Sensor Using a Graphite Pencil Electrode for Sensitive Quantification of Phenolic Antioxidants in Human Plasma and Food Samples

Mohamed Ismael, Emad F. Newair, Ahmed Refaat Bakr, Mohamed H. Khairy
Electroanalysis
Electrochemical sensors and biosensors
article

A Cost‐Effective Electrochemical Sensor Using a Graphite Pencil Electrode for Sensitive Quantification of Phenolic Antioxidants in Human Plasma and Food Samples

Mohamed Ismael, Emad F. Newair, Ahmed Refaat Bakr, Mohamed H. Khairy
article en

Abstract

Abstract The pressing challenge in electroanalysis revolves around the creation of a user‐friendly analytical sensor that is accessible to individuals lacking specialized expertise. Such sensor should offer minimal cost, while simultaneously ensuring high sensitivity and reproducibility. Herein, graphite pencil electrode (GPE) has emerged as a promising electrochemical sensor for the determination of polyphenolic compounds, including gentisic acid (GEN), gallic acid (GA), caffeic acid (CAF), and sinapic acid (SA). To comprehensively explore the electrochemical oxidation processes of these antioxidants, a range of electrochemical techniques, namely cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA), were deployed. The results of these investigations unveiled a diffusional oxidation wave associated with phenolic hydroxyl groups, involving a two‐electron/two‐proton loss step, occurring within the potential range of 0.4–0.6 V vs . Ag/AgCl. Crucially, the GPE exhibited the capacity to establish linear calibration curves for GEN, GA, CAF, and SA, encompassing concentrations from nanomolar to sub‐micromolar which highlighted by the corresponding limits of detection (LoD), recorded at 0.086, 0.046, 0.112, and 0.115 μM, respectively. The heightened sensitivity and reproducibility demonstrated by the GPE underscore its potential as an efficient tool for the determination of polyphenolic compounds. Beyond its analytical capabilities, the GPE displayed remarkable applicability in facilitating on‐site, cost‐effective determinations of polyphenolic compounds in both plasma and food samples. This versatility positions the GPE as a valuable asset in addressing the challenges associated with electrochemical analysis, making it an attractive option for a wide range of applications where simplicity, affordability, and reliability are paramount.

ElectroanalysisVol. 37(1)
Damanhour University (EG), Sohag University (EG)
Zero hunger
Openalex Percentile: Top 89%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.