Performance of the SOAR Speckle Instrument

Abstract The High Resolution Camera (HRCam) speckle imager at the 4.1 m Southern Astrophysical Research telescope is a highly productive instrument that has accumulated about 40K observations to date. Its performance (detected flux, level of the speckle signal, signal-to-noise ratio, and limiting magnitude) is studied here using both the actual data and realistic simulations, including the detector noise. In the calculation of the speckle power spectrum, signal clipping is essential to reduce the noise impact and maximize the sensitivity. Increasing exposure time of individual frames beyond 30 ms does not improve the limiting magnitude, which ranges from 11.5 to 14 mag under a seeing from 1.″6 to 0.″6 in the wide-band I filter. A gain of at least one magnitude is expected if the current electron multiplication CCD is replaced by a high-end CMOS detector with a subelectron readout noise. This study will help in planning, executing, and automating future speckle observations with HRCam and other speckle imagers.

Authors

Institutions

Publication Details

Journal
The Astronomical Journal
Published
2024-08-22
DOI
https://doi.org/10.3847/1538-3881/ad6153
Citations
1
Primary Topic
Adaptive optics and wavefront sensing
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the SOAR Speckle Instrument

Andreï Tokovinin
1 citations
The Astronomical Journal
Adaptive optics and wavefront sensing
0.34
article

Performance of the SOAR Speckle Instrument

Andreï Tokovinin
article en
1 citations

Abstract

Abstract The High Resolution Camera (HRCam) speckle imager at the 4.1 m Southern Astrophysical Research telescope is a highly productive instrument that has accumulated about 40K observations to date. Its performance (detected flux, level of the speckle signal, signal-to-noise ratio, and limiting magnitude) is studied here using both the actual data and realistic simulations, including the detector noise. In the calculation of the speckle power spectrum, signal clipping is essential to reduce the noise impact and maximize the sensitivity. Increasing exposure time of individual frames beyond 30 ms does not improve the limiting magnitude, which ranges from 11.5 to 14 mag under a seeing from 1.″6 to 0.″6 in the wide-band I filter. A gain of at least one magnitude is expected if the current electron multiplication CCD is replaced by a high-end CMOS detector with a subelectron readout noise. This study will help in planning, executing, and automating future speckle observations with HRCam and other speckle imagers.

The Astronomical JournalVol. 168(3)
Cerro Tololo Inter-American Observatory (CL)
Sustainable cities and communities
Openalex Percentile: Top 41%
Adaptive optics and wavefront sensing
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.