RF coil that minimizes electronic components while enhancing performance for rodent MRI at 7 Tesla

This study introduces a novel volume coil design that features two slotted end-plates connected by six rungs, resembling the traditional birdcage coil. The end rings are equipped with six evenly distributed circular slots, inspired by Mansfield's cavity resonator theory, which suggests that circular slots can generate a baseline resonant frequency. One notable advantage of this proposed coil design is its reduced reliance on electronic components compared to other volume coils, making it more efficient. Additionally, the dimensions of the coil can be theoretically computed in advance, enhancing its practicality. To evaluate the performance and safety of the coil, electromagnetic field and specific absorption rate simulations were simulated using a cylindrical saline phantom and the finite element method. Furthermore, a transceiver coil prototype optimized for 7 Tesla and driven in quadrature was constructed, enabling whole-body imaging of rats. The resonant frequency of the coil prototype obtained through experimental measurements closely matched the theoretical frequency derived from Mansfield's theory. To validate the coil design, phantom images were acquired to demonstrate its viability and assess its performance. These images also served to validate the magnetic field simulations. The experimental results aligned well with the simulation findings, confirming the reliability of the proposed coil design. Importantly, the prototype coil showcased significant improvements over a similarly-sized birdcage coil, indicating its potential for enhanced performance. The noise figure was lower in the prototype versus the birdcage coil (<i>NF</i><sub>birdcage</sub>-<i>NF</i><sub>slotcage</sub>= 0.7). Phantom image data were also used to compute the image SNR, giving SNR<sub>slotcage</sub>/SNR<sub>birdcage</sub>= 34.36/24.34. By proving the feasibility of the coil design through successful rat whole-body imaging, the study provides evidence supporting its potential as a viable option for high-field MRI applications on rodents.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2024-08-22
DOI
https://doi.org/10.1088/2057-1976/ad7265
Citations
2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RF coil that minimizes electronic components while enhancing performance for rodent MRI at 7 Tesla

Alejandro Villareal, Jelena Lazović, Fabian Vazquez, R. Martin et al.
2 citations
Biomedical Physics & Engineering Express
Advanced MRI Techniques and Applications
0.81
article

RF coil that minimizes electronic components while enhancing performance for rodent MRI at 7 Tesla

Alejandro Villareal, Jelena Lazović, Fabian Vazquez, R. Martin, A. O. Rodríguez, Sergio Solis-Najera
article en
2 citations

Abstract

This study introduces a novel volume coil design that features two slotted end-plates connected by six rungs, resembling the traditional birdcage coil. The end rings are equipped with six evenly distributed circular slots, inspired by Mansfield's cavity resonator theory, which suggests that circular slots can generate a baseline resonant frequency. One notable advantage of this proposed coil design is its reduced reliance on electronic components compared to other volume coils, making it more efficient. Additionally, the dimensions of the coil can be theoretically computed in advance, enhancing its practicality. To evaluate the performance and safety of the coil, electromagnetic field and specific absorption rate simulations were simulated using a cylindrical saline phantom and the finite element method. Furthermore, a transceiver coil prototype optimized for 7 Tesla and driven in quadrature was constructed, enabling whole-body imaging of rats. The resonant frequency of the coil prototype obtained through experimental measurements closely matched the theoretical frequency derived from Mansfield's theory. To validate the coil design, phantom images were acquired to demonstrate its viability and assess its performance. These images also served to validate the magnetic field simulations. The experimental results aligned well with the simulation findings, confirming the reliability of the proposed coil design. Importantly, the prototype coil showcased significant improvements over a similarly-sized birdcage coil, indicating its potential for enhanced performance. The noise figure was lower in the prototype versus the birdcage coil (<i>NF</i><sub>birdcage</sub>-<i>NF</i><sub>slotcage</sub>= 0.7). Phantom image data were also used to compute the image SNR, giving SNR<sub>slotcage</sub>/SNR<sub>birdcage</sub>= 34.36/24.34. By proving the feasibility of the coil design through successful rat whole-body imaging, the study provides evidence supporting its potential as a viable option for high-field MRI applications on rodents.

Biomedical Physics & Engineering ExpressVol. 10(5)
Universidad Autónoma de la Ciudad de México (MX), Universidad Autónoma Metropolitana (MX), Max Planck Institute for Intelligent Systems (DE), Universidad Nacional Autónoma de México (MX)
Openalex Percentile: Top 26%
Advanced MRI Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.