Interpretation of complex x-ray photoelectron peak shapes. I. Case study of Fe 2p3/2 spectra

Analyzing transition metal XPS peaks is widely used to determine surface composition and chemistry. However, these peaks have a complex structure, which is still the subject of investigation. Fe 2p analysis is a case in point where the multiplet structure and many-electron-effects lead to peak shapes that cannot be analyzed using standard approaches. Examination of the literature reveals that one of the most widely used approaches to data reduction when processing Fe 2p3/2 spectra involves using symmetric two- or three-component peak fitting with each peak effectively acting to capture a single chemical species (chemistry fit) in the complex spectra. Herein, this approach is compared to an envelope fit approach using Biesinger multiplet components of known iron oxides to determine how effective these methods are in reproducing iron oxide composition. Mixed oxide and metal XPS Fe 2p spectra were synthesized using reference spectra collected experimentally. For the first time, the accuracy and differences between the two approaches are reported. It is demonstrated that no meaningful conclusions can be drawn using single symmetric peaks to analyze complex Fe 2p3/2 spectra, implying that a large portion of the literature is flawed. The envelope fit approach, however, is shown to provide useful information regarding oxide ratios in mixed iron oxide materials, though limitations do exist. A methodology for evaluating the quality of XPS analysis of Fe 2p3/2 spectra is proposed for benchmarking new submissions so that reviewers, authors, and editors can assess these submissions.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Published
2024-08-22
DOI
https://doi.org/10.1116/6.0003804
Citations
25
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
4.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interpretation of complex x-ray photoelectron peak shapes. I. Case study of Fe 2p3/2 spectra

Majid Laleh, A.E. Hughés, Thomas R. Gengenbach, Christopher D. Easton et al.
25 citations
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Electron and X-Ray Spectroscopy Techniques
4.46
article

Interpretation of complex x-ray photoelectron peak shapes. I. Case study of Fe 2p3/2 spectra

Majid Laleh, A.E. Hughés, Thomas R. Gengenbach, Christopher D. Easton, Mark C. Biesinger
article en
25 citations

Abstract

Analyzing transition metal XPS peaks is widely used to determine surface composition and chemistry. However, these peaks have a complex structure, which is still the subject of investigation. Fe 2p analysis is a case in point where the multiplet structure and many-electron-effects lead to peak shapes that cannot be analyzed using standard approaches. Examination of the literature reveals that one of the most widely used approaches to data reduction when processing Fe 2p3/2 spectra involves using symmetric two- or three-component peak fitting with each peak effectively acting to capture a single chemical species (chemistry fit) in the complex spectra. Herein, this approach is compared to an envelope fit approach using Biesinger multiplet components of known iron oxides to determine how effective these methods are in reproducing iron oxide composition. Mixed oxide and metal XPS Fe 2p spectra were synthesized using reference spectra collected experimentally. For the first time, the accuracy and differences between the two approaches are reported. It is demonstrated that no meaningful conclusions can be drawn using single symmetric peaks to analyze complex Fe 2p3/2 spectra, implying that a large portion of the literature is flawed. The envelope fit approach, however, is shown to provide useful information regarding oxide ratios in mixed iron oxide materials, though limitations do exist. A methodology for evaluating the quality of XPS analysis of Fe 2p3/2 spectra is proposed for benchmarking new submissions so that reviewers, authors, and editors can assess these submissions.

Journal of Vacuum Science & Technology A Vacuum Surfaces and FilmsVol. 42(5)
Western University (CA), Commonwealth Scientific and Industrial Research Organisation (AU), Deakin University (AU), University of Wollongong (AU), CSIRO Manufacturing (AU)
Openalex Percentile: Top 5%
Electron and X-Ray Spectroscopy Techniques
4.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.